期刊文献+

Application of Power Electronics and Control for Dual Battery Packs Management with Voltage Balancing and State of Charge Estimation

Application of Power Electronics and Control for Dual Battery Packs Management with Voltage Balancing and State of Charge Estimation
在线阅读 下载PDF
导出
摘要 Energy storage, such as lead acid batteries, is necessary for renewable energy sources’ autonomy because of their intermittent nature, which makes them more frequently used than traditional energy sources to reduce operating costs. The battery storage system has to be monitored and managed to prevent serious problems such as battery overcharging, over-discharging, overheating, battery unbalancing, thermal runaway, and fire dangers. For voltage balancing between batteries in the pack throughout the charging period and the SOC estimate, a modified lossless switching mechanism is used in this research’s suggested battery management system. The OCV state of charge calculation, in the beginning, was used in conjunction with the coulomb counting approach to estimate the SOC. The results reveal that correlation factor K has an average value of 0.3 volts when VM ≥ 12 V and an average value of 0.825 when VM ≤ 12 V. The battery monitoring system revealed that voltage balancing was accomplished during the charging process in park one after 80 seconds with a SOC difference of 1.4% between Batteries 1 and 2. On the other hand, the system estimates the state of charge during the discharging process in two packs, with a maximum DOD of 10.8 V for all batteries. The project’s objectives were met since the BMS estimated SOC and achieved voltage balance. Energy storage, such as lead acid batteries, is necessary for renewable energy sources’ autonomy because of their intermittent nature, which makes them more frequently used than traditional energy sources to reduce operating costs. The battery storage system has to be monitored and managed to prevent serious problems such as battery overcharging, over-discharging, overheating, battery unbalancing, thermal runaway, and fire dangers. For voltage balancing between batteries in the pack throughout the charging period and the SOC estimate, a modified lossless switching mechanism is used in this research’s suggested battery management system. The OCV state of charge calculation, in the beginning, was used in conjunction with the coulomb counting approach to estimate the SOC. The results reveal that correlation factor K has an average value of 0.3 volts when VM ≥ 12 V and an average value of 0.825 when VM ≤ 12 V. The battery monitoring system revealed that voltage balancing was accomplished during the charging process in park one after 80 seconds with a SOC difference of 1.4% between Batteries 1 and 2. On the other hand, the system estimates the state of charge during the discharging process in two packs, with a maximum DOD of 10.8 V for all batteries. The project’s objectives were met since the BMS estimated SOC and achieved voltage balance.
作者 Stuart Brown Tsafack Pierre Fendji Marie Danielle Emmanuel Tanyi Musong L. Katche Stuart Brown;Tsafack Pierre;Fendji Marie Danielle;Emmanuel Tanyi;Musong L. Katche(Department of Electrical and Electronics Engineering, University of Buea, Buea, Cameroon)
出处 《Energy and Power Engineering》 CAS 2022年第12期762-780,共19页 能源与动力工程(英文)
关键词 State of Charge Battery Management System Lead Acid Battery State of Charge Battery Management System Lead Acid Battery
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部