Load Static Models for Conservation Voltage Reduction in the Presence of Harmonics

Load Static Models for Conservation Voltage Reduction in the Presence of Harmonics
在线阅读 下载PDF
导出
摘要 The Conservation Voltage Reduction (CVR) is a technique that aims to achieve the decrease of power consumption as a result of voltage reduction. The customer is supplied with the lowest possible voltage level compatible with the stipulated level by the regulatory agency. International Standards ANSI C84.1-2006 and IEEE std 1250-1995 specify the range of supply voltage to electronics equipment from 0.9 to 1.05 pu of nominal voltage. To analyse the CVR effect in distribution systems with different load characteristics (residential, commercial, industrial or a combination of these), mathematical load models are used. Typically, these equipment/load models are used to analyse load aggregation without any consideration of its nonlinearity characteristics. Aiming to analyse the nonlinear characteristics and its consequences, this paper presents a discussion of the neglected variables as well as the results of a set of measurements of nonlinear loads. Different mathematical models are applied to obtain them for each load. Using these models the load aggregation is evaluated. It is presented that although the models show adequate results for individual loads, the same does not occur for aggregated models if the harmonic contribution is not considered. Consequently, to apply the load model in CVR it is necessary to consider the harmonics presence and the model has to be done using only the fundamental frequency data. The discussion about the causes is done and the models are compared with the measurements. The Conservation Voltage Reduction (CVR) is a technique that aims to achieve the decrease of power consumption as a result of voltage reduction. The customer is supplied with the lowest possible voltage level compatible with the stipulated level by the regulatory agency. International Standards ANSI C84.1-2006 and IEEE std 1250-1995 specify the range of supply voltage to electronics equipment from 0.9 to 1.05 pu of nominal voltage. To analyse the CVR effect in distribution systems with different load characteristics (residential, commercial, industrial or a combination of these), mathematical load models are used. Typically, these equipment/load models are used to analyse load aggregation without any consideration of its nonlinearity characteristics. Aiming to analyse the nonlinear characteristics and its consequences, this paper presents a discussion of the neglected variables as well as the results of a set of measurements of nonlinear loads. Different mathematical models are applied to obtain them for each load. Using these models the load aggregation is evaluated. It is presented that although the models show adequate results for individual loads, the same does not occur for aggregated models if the harmonic contribution is not considered. Consequently, to apply the load model in CVR it is necessary to consider the harmonics presence and the model has to be done using only the fundamental frequency data. The discussion about the causes is done and the models are compared with the measurements.
作者 William Douglas Caetano Patrícia Romeiro da Silva Jota William Douglas Caetano;Patrícia Romeiro da Silva Jota(Electrical Engineer Department, Federal Centre of Technological Education (CEFET-MG), Belo Horizonte, Brazil)
出处 《Energy and Power Engineering》 2016年第2期62-75,共14页 能源与动力工程(英文)
关键词 CVR Load Model in the Presence of Harmonics Conservation Voltage Reduction Load Model Aggregation in the Presence of Harmonics CVR Load Model in the Presence of Harmonics Conservation Voltage Reduction Load Model Aggregation in the Presence of Harmonics
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部