期刊文献+

地铁车站应急照明供电系统的设计 被引量:4

Design for Emergency Lighting Power Supply System of the Metro Substations
在线阅读 下载PDF
导出
摘要 后备电源的设计与选择是保障车站应急照明系统在电源故障或者灾害情况下发挥作用的关键环节。通过比较UPS和EPS两种静止型后备电源后认为 ,在地铁车站应急照明系统中应采用EPS型静止型后备电源。从对电网的适应能力、满足负载要求的常规输出指标、输出能力和可靠性、智能管理和通信功能等四个方面系统分析了EPS的性能指标。 Design and selection of Spare Power Supply is the essential to emergency lighting power supply system. It is found that the Emergency Power Supply (EPS) adapted to emergency lighting of the substations on the basis of comparing Uninterrupted Power Supply (UPS) with EPS, which are two types of Static Spare Power Supply. The performance index of the EPS was analyzed including the ability to adapt the power network of the city, the general output performance index meeting the load requirement, the loading capability and reliability, intelligence management and communication. Finally, the methods ascertaining the raed capacity of EPS and storage battery, and some advertent things for system integration were introduced.
出处 《机械制造与自动化》 2004年第3期78-81,共4页 Machine Building & Automation
关键词 后备电源 应急电源 应急照明 Spare Power Supply Emergency Power Supply emergency lighting