用于小动物研究的数字X线成像系统 被引量:2

A Digital Radiography System for Small Animals and Specimen Imaging
在线阅读 下载PDF
导出
摘要 介绍一种用于小动物研究的数字X射线成像系统。该系统基于两个电荷耦合器件(CCD),并采用光纤耦合,其X射线管的焦点尺寸为20μm。对系统的几何模糊与放大倍率关系的研究,以及对调制传递函数(MTF)的测量,显示了该系统在空间分辨率特性方面的优势。最后对该系统在大鼠肠系膜血管药理学等方面的研究应用进行了展望。 A digital radiography system for small animal studies is introduced here. This system that is based on two CCD arrays, is a fiber-optics taper-coupled imaging system. Its X-ray source has a small focal spot of 20μm. The system shows its advantages in terms of its proper-ties of spatial resolution through the tradeoff between the geometric unsharpness and image magnification, and the measurement of MTF. The system's application, in prospect, to the rat mesentery study is discussed too in this paper.
出处 《中国医疗器械杂志》 CAS 2004年第3期179-181,209,共4页 Chinese Journal of Medical Instrumentation
基金 国家自然科学基金(No.60178028) 国家杰出青年科学基金(No.60025514)
关键词 数字X线成像系统 光纤耦合成像系统 空间分辨率 参数 digital radiography system fiber-optics taper-coupled imaging system spatial resolution
  • 相关文献

参考文献6

  • 1R.Fahrig et al.X-ray imaging using amorphous selenium Detective quantum efficiency of photoconductive image receptors for digital mammography.Med.Phys.1995,22(4):153-160
  • 2R.M.Nishikawa et al.Scanned projection digital mammography.Med.Phys.1987,14(5):717-727
  • 3H.Liu et al.Design of a dual CCD configuration to improve the signal-to-noise ratio.Med.Phys.2000,27(10):2435-2437
  • 4Hiroshi Fujita et al A simple method for determining the modulation transfer function in digital radiography.IEEE Trans Med Imag.1992,11(1):34-39.
  • 5Samei et al A method for measuring the presampled MTF of digital radiographic systems using an edge test device.Med.Phys.1998,25(1):102-113.
  • 6Fabrice Ouandji et al.Characterization of a CCD-based digital X-ray imaging system for small-animal studies properties of spatial resolution.2002,41(13):2420-2427.

同被引文献42

  • 1仲爱军,龚辉,骆清铭.适于小动物研究的微型CT系统的研制[J].中国医疗器械杂志,2004,28(5):330-333. 被引量:3
  • 2梁丽红,路宏年.X射线数字成像系统传递函数模型[J].北京航空航天大学学报,2005,31(9):1018-1021. 被引量:4
  • 3Fujita H,Tsai D Y,Itoh T,et al. A simple method for determining the modulation transfer function in digital radiography[J].IEEE Transactions on Medical Imaging,1992,11 (1) 34-39.
  • 4Samei E, Flynn M, Reimann D. A method for measuring the presampled MTF of digital radiographic systems using an edge test device [J]. Medical Physics, 1998, 25 (1) : 102-113.
  • 5Illers H,Buhr E,Gunther-Kohfahl S,et al. Measurement of the modulation transfer function of digital X-ray detectors with an opaque edge-test device [J]. Radiation Protection Dosimetry,2005,114( 1/2/3) 214-219.
  • 6Zhu Yuemin, Kaftandjian Valerie ,Peix Gilles ,et al. Modulation transfer function evaluation of linear solid- state X-ray-sensitive detectors using edge techniques [J]. Appl Opt, 1995,34 (22) :4937-4943.
  • 7Tatsuya Yamazaki,Makoto Nokita,Shinsuke Hayashida, et al. A method to measure the presampling MTF using a novel edge test device and algorithm [C]//Medical Imaging 2004: Physics of Medical Imaging. San Diego,CA, USA : SP1E, 2004 : 696-704.
  • 8Cunningham I A, Reid B K. Signal and noise in modulation transfer function determinations using the slit, wire, and edge techniques [J].Medical Physics, 1992,19 (4) : 1037-1044.
  • 9Samei E,Dobbins J,Saunders R,et al. IEC 62220-1: Medical electrical equipment--Characteristics of digital X-ray imaging devices (Part 1) :Determination of the detective quantum efficiency[C]// International Electrotechnical Commission (IEC) . Geneva , Switzerland , 2003.
  • 10Illers H, Buhr E, Hoeschen C. Measurement of the detective quantum efficiency (DQE)of digital X-ray detectors according to the novel standard IEC 62220-1 [J]. Radiation Protection Dosimetry, 2005, 114 (1/2/3) : 39- 44.

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部