火灾规律双重性模型及其对室内漏油火灾的分析 被引量:3

DOUBLE QUALITY MODEL AND ITS ANALYSIS OF OILSPILL FIRES IN A COMPARTMENT
在线阅读 下载PDF
导出
摘要 火灾的规律具有双重性:确定性和随机性。只有既研究其确定性又研究其随机性,并进而研究二者的综合才能完整地认识火灾的规律。本文提出火灾双重性规律的学术思想,通过构造室内漏油火灾的确定性和随机性模型,阐明运用火灾双重性规律表述火灾过程的具体方法。文中用微机实施的大量计算表明,该模型能方便地预言:发生室内漏油火灾时,室内设备是否会损坏以及可能被损坏的概率. Fire has double quality:determinability and probability.Only when we study not only its deter-minability but also its probability and furthermore study synthetically the above two,can we recognizeintegral regularity of fire.The academic thought of double quality of fire has been put forward in thisarticle,and the concrete method of its application to demonstrate fire process has been clarified by con-structing deterministic and probabilitic model for oilspill fires in a compartment.A great quantity ofcalculation on computer shows,this model can predict conveniently whether the equipment in a com-partment will be damaged in an oilspill fire and the possibility of its damage.
作者 范维澄 陈莉
出处 《自然灾害学报》 CSCD 1992年第3期31-38,共8页 Journal of Natural Disasters
关键词 火灾模型 漏油 室内设备 预测 Double quality of fire Model for oilspill fires Fire predict for equipment in a compartment
  • 相关文献

参考文献3

  • 1J. R. Lawson,J. G. Quintiere. Slide rule estimates of Fire Growth[J] 1985,Fire Technology(4):267~292
  • 2Vytenis Babrauskas. Estimating large pool fire burning rates[J] 1983,Fire Technology(4):251~261
  • 3B. J. McCaffrey,J. G. Quintiere,M. F. Harkleroad. Estimating room temperatures and the likelihood of flashover using fire test data correlations[J] 1981,Fire Technology(2):98~119

同被引文献26

引证文献3

二级引证文献19