期刊文献+

氢氧化钠标准溶液浓度不确定度的评定 被引量:7

EVALUATION OF THE UNCERTAINTY FOR THE CONCENTRATION OF SODIUM HYDROXIDE STANDARD SOLUTION
在线阅读 下载PDF
导出
摘要 评定了按照GB/T 6 0 1- 2 0 0 2方法配制和标定氢氧化钠标准溶液浓度的不确定度。从仪器、试剂、操作及实验环境方面分析了不确定度来源 ,对不确定度分量进行了分析、计算、合成。氢氧化钠标准溶液浓度的不确定度主要由标定时消耗体积的读数误差产生。在试剂纯度、仪器精度符合规定时 ,氢氧化钠标准溶液浓度的相对扩展不确定度为 0 .14 %。 The uncertainty for the concentration of sodium hydroxide standard solution was evaluated. The solution was prepared and standardized with GB/T 601-2002 method, the components of the uncertainty caused by the apparatus, the reagents, the operator and the environment were analyzed and caculated. It showed by the results that the uncertainty was mainly caused by the titrant volume. When the reagent and the apparatus were conformed to the request, the related expanded uncertainty was 0.14%.
作者 邓乐平
出处 《化学分析计量》 CAS 2004年第3期1-5,共5页 Chemical Analysis And Meterage
关键词 氢氧化钠 浓度 不确定度 容量分析法 邻苯二甲酸氢钾 concentration of the standard solution, sodium hydroxide, uncertainty, evaluation
  • 相关文献

参考文献3

  • 1GB/T601—2002.化学试剂标准滴定溶液的制备.[S].,..
  • 2JJG98—1990.非自动天平.[S].,..
  • 3JJG196—1990.常用玻璃量器检定规程.[S].,..