冲击片起爆系统中能量转换开关性能研究 被引量:1

Study on the Performance of Change-over Switch Used in the Slapper Initiating System
在线阅读 下载PDF
导出
摘要 对冲击片起爆试验系统的能源供给系统中使用的能量转换开关进行了选择确定,采取固定电极间隙、给场畸变开关充以不同压力的惰性气体(纯氩气、高纯氮)的方法实现了对充电电压的调节。试验表明,所选用的开关性能完全满足冲击片起爆感度试验装置起爆炸药的需要。 The change-over switch used in the slapper initiating system is studied. The electric field distortion switch is selected to transform energy. When the electrode gap of the electric field distortion switch is determined, by fulling the inert gas with different pressure to the internal of change-over switch, the experimental voltages can be adjusted. The performance test has been carried out. The results make clear that the electric field distortion switch can meet the need of slapper initiator.
出处 《火工品》 CAS CSCD 北大核心 2004年第1期1-3,23,共4页 Initiators & Pyrotechnics
基金 山西省自然科学基金资助项目(20021064)
关键词 冲击片起爆系统 场畸变开关 爆炸 起爆炸药 Slapper Electric field distortion switch Explosion
  • 相关文献

参考文献4

  • 1谭迎新,张景林,王桂吉.电爆炸导体驱动小飞片起爆技术研究[J].兵工学报,2003,24(2):253-256. 被引量:8
  • 2Tan ying-xin,Wang gui-ji,Zhang jing-lin,Jiang li. Experimental study on the power supply circuit parameters of a short-duration shock initiating system [C]. Progress in safety science and technology. Vol. Ⅲ. Science press, 2002: 1 506-1 508.
  • 3蒋丽.飞片起爆的能量表征法研究 [M].太原:华北工学院,2003.13-14.
  • 4王桂吉.飞片感度试验方法研究[M].太原:华北工学院,2003.18-20.

二级参考文献8

  • 1李茂昌.耐热炸药HNAB、HNS、LX-15的冲击起爆性能[J].火工品,1992,(4).
  • 2经福谦.动态超高压技术(二)[J].爆炸与冲击,1984,4(4):24-26.
  • 3王治平 欧阳登焕 彭德志.HNS炸药的小面积短脉冲冲击引爆特性[J].爆炸与冲击,1987,7(2):154-158.
  • 4米夏兹ΓA著 邵贵荣译.大功率毫微秒脉冲的产生[M].北京:原子能出版社,1982.161-175.
  • 5王莹.电爆炸导体及其应用.爆炸与冲击,1986,6(2):184-192.
  • 6Richardson D D, Northeast E D, Ryan P F X. An Exploding Foil Plate Generator. MRL-R-1133, 1988.1-- 10.
  • 7杨振英.爆炸箔起爆器的设计及影响因素试验.火工品,1999,(4):18-27.
  • 8米夏兹гA著 邵贵荣译.大功率毫微秒脉冲的产生[M].北京:原子能出版社,1982.161-175.

共引文献7