摘要 目的 :复习文献 ,并进一步讨论常规剂量下影响CT检出肺结节的因素。方法 :选择肺转移瘤 2 0例 ,分别在不同层厚、重建间隔以及螺距情况下扫描 ,统计在每一扫描条件下检出的肺结节的大小、数量、部位 ,讨论扫描条件、结节大小、结节部位与肺结节检出率之间的关系。结果 :扫描层厚薄、重建间隔小、螺距值小、检出的肺结节数越多 ,更多的是提高了微结节的检出 ;与肺血管影、肺门影、心旁纵隔影、横膈影重叠的肺结节容易漏检。结论 :常规剂量扫描条件下 ,扫描层厚、重建间隔、螺距、结节大小、结节位置均可影响结节的检出。 Objective:To review literature and further evaluate the factors influencing lung nodules detection by standard dose scanning.Methods:20 patients with lung metastasis were scanned by CT with different schemes,including different slice thickness,different reconstruction interval and pitch.The nodules size,number and position,were measured and the correlativity of scan schemes,nodule size,nodule position and the detecting rate of the nodules were observed.Results:The thinner the slice thickness and the smaller the reconstruction interval and the smaller the pitch,the more nodules are found out,mainly more tiny nodules are found out;nodules adjacenting to or overlapping on pulmonary vessels,hilum of lung,heart border and diagram are easly not found out.Conclusion:By standard dose schemes,the slice thickness,reconstruction interval,pitch,nodule size and position all influence the defection of the lung nodules.
出处 《医学影像学杂志》 2004年第2期98-100,共3页 Journal of Medical Imaging
关键词 肺结节 体层摄影术 X线计算机 优化方案 Lung nodule Tomography,X-ray computed Optimizing scheme
  • 相关文献

参考文献7

二级参考文献10

共引文献49

同被引文献26

  • 1马大庆.多层螺旋CT多平面重建对肺内病变的诊断价值[J].诊断学理论与实践,2004,3(3):142-143. 被引量:5
  • 2强金伟,周康荣,蒋亚平,叶宣光,王群,徐松涛,谭黎杰.多层螺旋CT与病理对照研究孤立性肺结节与支气管的关系[J].中华放射学杂志,2003,37(11):992-996. 被引量:64
  • 3Glossary of terms for thoracic radiology:recommendations of the nomenclature committee of the fleischner society.Am J Roentgenol,1984,143:509
  • 4Leef JL,Klein IS.The solitary pulmonary nodule.Radiol Clin North Am,2002,40:123
  • 5Itoch S,Ikeda M,Mori Y,et al.Lung:feasibility of a method for changing tube current during low-dose helical CT.Radiology,2002,224:905
  • 6Shingo I,Naoki M,Mitsuru I,et al.Solitary pulmonary nodules:optimal slice thickness of high-resolution CT in differentiating malignant from benign.Clinical Imaging,2004,28:322
  • 7Eibel R,Turk TR,Kulinna C,et al.Multidetector-row CT of the lungs:multiplanar reconstructions and maximum intensity projections for the detection of pulmonary nodules.Pofo Fortschr Geb RoentgenstrNeuen Bildgeb Verfahr,2001,173:815
  • 8Gould MK,Maclean CC,Kuschner WG,et al.Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions:a meta-analysis.JAMA,2001,285:914
  • 9Armato Ⅲ SG,Altman MB,Wilkie J.Automated lung nodule classification following automated nodule detection on CT:a serial approach.Med.Phys,2003,30:1188
  • 10Quekel LO,Kessels AG,Goei R,et al.Miss rate of lung cancer on the chest radiograph in clinical practice.Chest,1999,115:720

引证文献2

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部