期刊文献+

BX-1型喷雾器喷洒过氧乙酸气溶胶的消毒效果观察 被引量:4

OBSERVATION ON DISINFECTION EFFICACY OF PERACETIC ACID AEROSOL GENERATED BY ATOMIZER TYPE BX-1
暂未订购
导出
摘要 在实验室内测定了BX-1型气溶胶喷雾器的雾化性能。结果表明,该机雾化粒谱小而集中,小于20μm的雾粒达90%以上。在室内,所喷过氧乙酸气溶胶,当作用30分钟时,对表面污染的白色葡萄球菌和类炭疽杆菌芽胞的消毒有效浓度分别为0.1%和1.6%。 The atomizer type BX-1 is a kind of portable electro-atomizer developed recently in China. It is 45×11×20cm in size, 3.5kg in weight and has a disinfectant container of 1 L capacity. It can be operated by either direct current or alternating current. It was indicated by laboratory measurement that the size of the aerosol particles generated by the atomizer was concentrated within a small range with over 90% of the particles being smaller than 20μm in diameter no matter whether aqueous preparation or oil preparation was used. When the atomizer was used for indoor spray of peracetic acid, the effective concentration of the disinfectant with a 30 min contact time for disinfection of the cloth strips contaminated by Staphylococcus albus or spores of Bacillus anthracoides was 0.1% or 1.6% respectively.
出处 《中国消毒学杂志》 CAS 北大核心 1992年第3期167-170,共4页 Chinese Journal of Disinfection
关键词 气溶胶 过氧乙酸 消毒剂 消毒器 aerosol atomizer peracetic acid surface disinfection
  • 相关文献

同被引文献14

  • 1肖楚华.乙型肝炎病毒标志物在消毒效果评价中应用的意义[J].中国消毒学杂志,1993,10(1):39-41. 被引量:6
  • 2严碧涯.结核病的院内感染和发病[J].中国防痨杂志,1994,16(4):181-184. 被引量:8
  • 3张本,王忠仁,童小玫,吴兆儒,宛淑贤.结核病房空气中结核分支杆菌检测方法研究[J].中华结核和呼吸杂志,1997,20(2):101-103. 被引量:4
  • 4郑子颖 余贺.分枝杆菌.医学微生物学[M].北京:人民卫生出版社,1983.512-518.
  • 5王撷秀 索奎荣 等.流行病学第二卷(第二版)[M].北京:人民卫生出版社,1979.672-681.
  • 6苏焯 李影林.分枝杆菌属及其微生物学检查法.临床微生物学及检验[M].长春:吉林科学技术出版社,1991.219-235.
  • 7中华人民共和国卫生部.《消毒技术规范--实验技术规范》[M].北京:中华人民共和国卫生部,1999.92-95.
  • 8.消毒技术规范[S].[S].中华人民共和国卫生部,2002,11..
  • 9中华人民共和国卫生部.公共场所集中空调通风系统卫生管理办法[S].2006.
  • 10中华人民共和国卫生部.公共场所集中空调通风系统卫生规范[S].2006.

引证文献4

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部