摘要
对14所医院正在使用的5种消毒液采样384份。检测结果表明,细菌总超标率为22.14%,HBsAg检出率为17.19%。乡镇医院污染最为严重,乙醇与过氧乙酸污染较多。使用时间长,更换药液时不清洗消毒容器,用于消毒侵袭性器械者污染均较严重。
Investigation on bacterial and HBsAg contamination of disinfectant solution in use was carried out in hospitals of Linyi Prefecture. Of 384 samples examined, rate of bacterial contamination beyond permissible limit was 22.14%(total bacterial count exceeding 250/ml was considered as beyond permissible limit), and positive rate for HBsAg was 17.19%. It was indicated in the investigation that:(1) the contamination in hospitals of villages and towns was heavier than that in hospitals of cities;(2) among solutions of various disinfectants such as bromogeramine, ethyl alcohol, tinctura iodi, peracetic acid and sodium dichloroisocyanurate, the solutions of ethyl alcohol and peracetic acid were most frequently contaminated;(3) the longer the duration of use, the heavier the contamination;(4) the chance of contamination would increase if the container had not been cleaned and disinfected during change of disinfectant solution;(5) the HBsAg positive rate of the disinfectant solution used to disinfect invasive instruments was higher than that used to disinfect ordinary instruments(25.83% vs 8.63%) because the HBV in patient blood was likely to be carried into the disinfectant solution in the former case.
出处
《中国消毒学杂志》
CAS
北大核心
1992年第1期35-38,共4页
Chinese Journal of Disinfection
关键词
细菌污染
抗感染药
医院
contamination of disinfectant
HBsAg contamination
bacterial contamination