摘要
给水温度是影响电厂机组经济运行的一项重要指标.以热力试验为基础,分析了耒阳电厂200MW机组运行中给水温度低的原因,并应用等效热降法进行经济性计算,最后提出了改进措施.
The feed-water temperature is an important criterion that affects the economical operation of turbo-generator unit in a power plant. On the basis of the thermal performance test, the reason for the lower temperature of 200 MW turbo-generator unit in Leiyang Power Plant is analyzed, and the economic calculation is performed with the method of equivalent enthalpy drop. At last, the handling measures are given.
出处
《长沙电力学院学报(自然科学版)》
2004年第1期51-54,共4页
JOurnal of Changsha University of electric Power:Natural Science