摘要
推导出安装调谐液体阻尼器(TLD)的建筑结构在简谐地震作用下的等效阻尼比,并对影响等效阻尼比的各个参数进行了研究,最后求得最优化参数.
The formula of equivalent damping ratio of high-rise structure buildings with TLD system under a simple harmonic earthquake action was deduced. The parameters that contribute to the formula of equivalent damping ratio were studied, and the optimization parameters were got in the end.
出处
《天津城市建设学院学报》
CAS
2004年第1期9-13,共5页
Journal of Tianjin Institute of Urban Construction