摘要
在2L高压间歇反应釜中,系统地研究了湿式氧化对乳化液废水的CODCr,TOC去除效果及影响因素。研究表明:温度是影响湿式氧化效果的关键因素,湿式氧化温度以220℃为宜,进水CODCr质量浓度为48000mg L时反应2h,CODCr和TOC去除率分别达86 4%,79 5%;供氧不足氧化受到显著限制,供氧量以(1 0~1 25)p(O2) 为宜;该法在较宽浓度范围内仍具有良好的处理效果;进水pH值对有机物氧化影响较小。
A systematic study on wet air oxidation (WAO) of highly concentrated emulsification wastewater was performed in a 2 L high-pressure batch autoclave,with emphasis on the removal effect of COD_(Cr),TOC and influence factors.The experimental results indicated that the temperature was the key factor and the best feasible temperature was 220 ℃,and that 86.4% of COD_(Cr) and 79.5% of TOC (initial COD_(Cr) 48 000 mg/L) in the wastewater were removed in 2 h.Oxidation was restricted without enough oxygen,it was fitting when the supply of oxygen was (1.0~1.25) p(O_2)~*.WAO had a good performance in the treatment of emulsified wastewater in a wider range.The pH of input water had little influence on the oxidaton efficiency.
出处
《环境科学研究》
EI
CAS
CSCD
北大核心
2004年第2期38-41,共4页
Research of Environmental Sciences
基金
高等学校博士学科点专项科研基金资助项目(20010247004)
关键词
乳化液废水
湿式氧化
温度
供氧量
PH
emulsification wastewater
wet air oxidation
temperature
supply of oxygen
pH