期刊文献+

Typical application of Rogowski coils in inspection of electrobath

Typical application of Rogowski coils in inspection of electrobath
在线阅读 下载PDF
导出
摘要 During the aluminum electrolytic roasting process,each component of the electrobath of aluminum performs unsteadily when the electrolytic bath is in the pre-roasting stage. It is important to monitor the currents of the anodes and the cathodes of the aluminum electrobath at regular intervals. Both practice and investigation indicate that Rogowski coil can be adopted to measure heavy direct current of the anodes and the cathodes of the aluminum electrobath. The paper not only introduces the typical application of the Rogowski coil to inspect the state of aluminum electrobath in the roasting process, but also analyzes the principles of the coil sensor including its dynamic properties and some important measurement results respectively. The optimal parameters of the coil can be simulated by means of an advanced simulation tool: simulink tools based on MATLAB soft environment. Based on the gathered current data, an even-current coefficient has been introduced, and the current curve can be drawn. Since they are applied in AL-Electrolyzing, it is possible to distinguish the anode of which the current is not evenly distributed, and to take adjusting measures over a period of time to ensure that the current is evenly distributed. During the aluminum electrolytic roasting process,each component of the electrobath of aluminum performs unsteadily when the electrolytic bath is in the pre-roasting stage. It is important to monitor the currents of the anodes and the cathodes of the aluminum electrobath at regular intervals. Both practice and investigation indicate that Rogowski coil can be adopted to measure heavy direct current of the anodes and the cathodes of the aluminum electrobath. The paper not only introduces the typical application of the Rogowski coil to inspect the state of aluminum electrobath in the roasting process, but also analyzes the principles of the coil sensor including its dynamic properties and some important measurement results respectively. The optimal parameters of the coil can be simulated by means of an advanced simulation tool: simulink tools based on MATLAB soft environment. Based on the gathered current data, an even-current coefficient has been introduced, and the current curve can be drawn. Since they are applied in AL-Electrolyzing, it is possible to distinguish the anode of which the current is not evenly distributed, and to take adjusting measures over a period of time to ensure that the current is evenly distributed.
作者 郭红 贾正春
出处 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2004年第1期103-108,共6页 哈尔滨工业大学学报(英文版)
关键词 rogowski coil current monitoring system simulation even current distribution dilapidation detection Rogowski线圈 电镀浴 电流分布 导电性
  • 相关文献

参考文献3

二级参考文献10

共引文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部