期刊文献+

二级G-M制冷机(6W/20K)性能测定 被引量:6

Capacity Measurement of Two-stage G-M Cryocooler
在线阅读 下载PDF
导出
摘要 简要介绍了国内外 G- M制冷机的应用、发展背景、工作原理。由于 G- M制冷机有性能可靠、寿命长、振动小、温度低、冷量大等优点 ,在多种领域得到广泛的应用。文中进一步说明了实验室测定二级 G- M制冷机制冷量的方法 ,及所用的设备、材料 ,对测试结果进行分析 ,为进一步改进奠定基础。文中二级 G- M制冷机性能指标为 :>6 W/ 2 0 K,降温时间为 6 0 m Based on the development situation of G-M cryocooler, the measurement method of capacity in the laboratory is clarified. The capacity of the cryocooler's is beyond 6W/20K and its cooldown time is about 60min which can supply reference for the improvement of the G-M cryocooler structure. G-M cryocooler is widely used because its advantage such as low vibration, high dependence, low temperature, high capacity etc. In a word, the future for the G-M cryocooler is bright.
出处 《低温与超导》 CAS CSCD 北大核心 2004年第1期6-8,21,共4页 Cryogenics and Superconductivity
关键词 制冷机 性能测定 制冷量 换热器 压缩机 G-M cryocooler, Capacity, Measurement
  • 相关文献

参考文献3

  • 1Graham Walker,Cryocoolers Part 1:Fundamentals,Plenum Press,New York.1 983.
  • 2Mc Mahon H O.Hoffman w E,A new low—temperature gas expansion cycle,partⅡ,Advan.In Cryo.Eng.1960, (5).
  • 3Gifford W E,The Gifford-Mcmahon cycle,Advan.In Cryo.Eng.,1966,(11).

同被引文献27

  • 1景加荣.F3H红外定标试验用空间环模设备[J].航天器环境工程,2008,25(4):369-372. 被引量:8
  • 2赵保志,王秋良,宋守森,雷沅忠,戴银明,黄晖,王晖.G-M制冷机作为冷凝泵在传导冷却超导磁体系统中的应用[J].低温工程,2004(5):18-21. 被引量:3
  • 3边绍雄,等.低温制冷机[M].北京:机械工业出版社,1991.
  • 4Li Rui. Great Progress in Magnetic Regenerator Material and 4K G - M Cryocooler [ C]. ICCR98,1998.
  • 5Li Rui. Great Progress in Magnetic Regenerator Material and 4 K GM Cryocooler[C]. ICCR98, 1998.
  • 6罗吉友.索尔文制冷机低温泵[J].真空与低温,1997,3(1):1-4. 被引量:1
  • 7Balle C H, Casas J, Rieubland J M, et al. Influence of thermal cycling oncryogenic thermometers, 1999.
  • 8Balle C, Casas J, Thermeau J P. Cryogenic thermometer calibration facility at CERN [ M ] //Advances in Cryo- genic Engineering,Springer US, 1998:741 - 748.
  • 9黄志秀,冯仰浦.降温速率可控的低温生物实验装置[J].低温与超导,1986(4):1-7.
  • 10Besley L M, Peng L. Stability studies on Chinese germanium resist- ance thermometers designed for use in magnetic fields[ J ]. Review of Scientific Instruments, 1991, 62(6) : 1587-1590.

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部