摘要
在闭合导线内业计算中,由于连接角没有检核条件,因而对连接角未进行改正。连接角也是一个测量值,必然存在误差。本文就此进行了分析,并提出了一种新的方法,以防止连接角出错,提高成果的可靠性,对实际工作有一定的参考价值。
In office calculation of closed traverse, the angle of connection is not corrected, because there is no check condition. The error of its measureing valueis impossible to avoid, the paper has made a detail analysis and offered a new method having a certain practical value in order to prevent mistake of the angle and to increase reliabilty of the result.
出处
《西安矿业学院学报》
北大核心
1992年第1期65-70,共6页
Journal of Xi'an University of Science & Technology
关键词
闭合导线
连接角
平差
测量
closed traverse, angle of connection, adjustment