本文提出了电解电容器用高纯铝箔晶粒择优取向测量及表述的新方法,引入了表征参量,分析了常规反极图测量的不足之处。这里提供的方法远比极图表述简单,不需专用设备,并且和工艺要求匹配。
This paper establishes a new expression and measurment method of texture for pure aluminium foil in electrolysis capacitor and analyses the disadvantages of the conventional inverse pole figure measurment. The new method proposed in this paper is more simple than the pole figure expression, doesn't need special equipment and can fit the technological requirement.