期刊文献+

共光路/共模块自适应光学数据融合方法 被引量:3

Data Fusion of the Two Hartman-Shack Wavefront Sensors in the Common Path/Common Mode Adaptive Optics System
原文传递
导出
摘要 研究了在CP/CM系统中 ,两个哈特曼夏克波前传感器用于控制一套波前校正器件的几种数据融合方法 ,通过复原矩阵的条件数分析了斜率数据向量的扰动和复原矩阵的扰动对系统控制电压的影响 ,得到了相应的公式。实现了CP/CM自适应光学闭环实验 ,并且利用实际系统比较了几种数据融合方法 ,认为现有工程技术条件下 ,加修正因子斜率融合和电压融合是可行的办法 ,二者在控制电压的得到上是等价的 ,不同之处将表现在波前处理机。 In the common path/common mode(CP/CM) adaptive optics(AO) system,two Hartman-Shack (H-S) wavefront sensors are used to realize the aberration sensing in the whole light path,controlling of a set of wavefront corrector and compensation of the aberration in the whole light path. Here the data fusion methods of the two H-S sensors in the CP/CM AO system are studied and the effects of the disturbance of the vector of slope data and the Reconstruction matrix to the controlling voltage are analyzed through the condition number of the reconstruction matrix. Corresponding formula are given. The close loop experiment of CP/CM is achieved. Modified slope and voltage data fusion methods are suitable to the engineering under the existing technology condition. They are equivalent in the finding of the controlling voltage,but the wavefront processors will be different.
出处 《光学学报》 EI CAS CSCD 北大核心 2004年第1期131-136,共6页 Acta Optica Sinica
关键词 共光路/共模块自适应光学 数据融合 哈特曼-夏克波前传感器 条件数 斜率融合 电压融合 adaptive optics common path/common mode data fusion Hartman-Shack wavefront sensors condition number
  • 相关文献

参考文献4

二级参考文献9

共引文献20

同被引文献24

引证文献3

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部