摘要 本文探索了自制起搏电极在心脏电生理研究中的应用 ,通过选择适当的材料 ,分为三部分制作电极 :极片部分、起搏器接口部分、焊封与绝缘。最后 ,将电极缝合于犬的心脏进行起搏。 Cardiac pacing leads are indispensable in the research of cardiac lelctrophsiology.We explored a type of pacing lead and sutured it on dog's heart.The pacing part is made of silver patch;the connector is combined by several small components.After the pacing part and the connetcor are connected,the lead is insulated.The self made lead performs well on dog's heart.
出处 《上海生物医学工程》 2003年第4期23-25,共3页 Shanghai Journal of Biomedical Engineering
关键词 心脏电生理 动物实验 永久起搏电极 电极导线 起搏器接口 cardiac electrophysiology cadiac pacing pacing lead
  • 相关文献

参考文献2

  • 1单兆亮,王玉堂,时向民,Mattias Duytschaever,Maurits A.Allessie.持续性心房颤动山羊模型的心房单极电极标测[J].中国心脏起搏与心电生理杂志,2002,16(3):212-215. 被引量:6
  • 2Riegger AJ,Liebau G.The renin-angiotensin-aldosterone system,antidiuretic hormone and sympathetic nerve activity in an experimental model of congestive heart failure in the dog.Clin Sci (Lond).1982,May;62(5):465-469

二级参考文献18

  • 1[1]Konings KTS,Kirchhof CJHJ,Smeets JLRM,et al.High-density mapping studies of electrically induced atrial fibrillation in humans[J].Circulation,1994,89:1665
  • 2[2]Wijffels MCEF,Kirchhof CJHJ,Dorland R,et al.Atrial fibrillation begets atrial fibrillation:a study in awake chronically instrumented goats[J].Circulation,1995,92:1954
  • 3[3]Duytschaever M,Danse P,Eijsbouts S,et al,The window of inducibility of atrial fibrillation is determined by critical conduction block within Bachmann′s bundle(Abstract)[J].PACE,1999,22(Ⅱ):880
  • 4[4]Sih HJ,Zipes DP,Berbari EJ,et al.Differences in organization between acute and chronic atrial fibrillation in dogs[J].J Am Coll Cardiol,2000,36:924
  • 5[5]Ramdat Miser AR,Opthof T,van Hemel NM,et al.Increased dispersion of "refractoriness" in patients with idiopathic paroxysmal atrial fibrillation[J].J Am Coll Cardiol,1992,19:1531
  • 6[6]Fareh S,Villemaire C,Nattel S.Importance of refractoriness heterogeneity in the enhanced vulnerability to atrial fibrillation induced by tachycardia-induced atrial electrical remodeling[J].Circulation,1998,98:2202
  • 7[7]Wells JL,Karp RP,Kouchoukos NT,et al.Characterization of atrial fibrillation in man:Studies following open heart surgery[J].PACE,1978,1:426
  • 8[8]Moe GK,Abildskov JA.Atrial fibrillation as a self-sustained arrhythmia independent of focal discharge[J].Am Heart J,1959,58:59
  • 9[9]Allessie MA,Lammers WJEP,Bonke FIM,et al.Experimental evaluation of Moe's multiple wavelets hypothesis of atrial fibrillation.In:Zipes DP,Jalife J eds.Cardiac Electrophysiology and Arrhythmias[M].New York:Grune & Stratton Inc.,1985.265
  • 10[10]Konings KTS,Smeets JLRM,Penn OC,et al.Configuration of unipolar atrial electrograms during electrically induced atrial fibrillation in humans[J].Circulation,1997,95:1231

共引文献5

同被引文献16

  • 1植入性心脏起搏器治疗:目前认识和建议(2010年修订版)[J].中国继续医学教育,2011,3(11):40-54. 被引量:13
  • 2Beck H, Boden WE, Patibandla S, et al. 50th Anniversary of the first successful permanent pacemaker implantation in the United States: historical review and future directions [J]. Am J Cardiol, 2010,15;106(6) :810 -818.
  • 3Epstein AE, Baker JH 2nd, Beau SL, et al. Performance of the St. Jude Medical Riata leads [ Jl. Heart Rhythm, 2009,6 (2) : 204 - 209.
  • 4Palmisano P, Accogli M, Zaccaria M, et al. Rate, causes, and impact on patient outcome of implantahle device complications re- quiring surgical revision: large population survey from two centres in Italy [J]. Europace, 2013,15(4) :531 -540.
  • 5Crossley GH. Cardiac pacing leads [ Jl. Cardiol C1in,2000, 18 (1) :95 -112.
  • 6Yee R, Gadler F, Hussin A, et al. Novel active fixation mecha- nism permits precise placement of a left ventricular lead : Early re- suits from a multicenter clinical study [ J ]. Heart Rhythm, 2014, 11(7) :1150- 1155.
  • 7Rickard J, Taborsky M, Bello D,et al. Short - and long - term electrical performance of the 5086 MRI pacing lead [ J ]. Heart Rhythm, 2014,11 (2) :222 - 229.
  • 8Epstein AE, DiMarco JP, Ellenbogen KA, et al. 2012 ACCF/ AHA/HRS focused update incorporated into the ACCF/AHA/ HRS 2008 guidelines for device - based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society [ J]. J Am Coll Cardi- ol, 2013,61(3) :e6 -e75.
  • 9Ghani A, Delnoy PP, Ramdat Misier AR, et 81. Incidence of lead dislodgement, malfunction and perforation during the first year following device implantation [ J ]. Neth Heart J, 2014,22 (6) : 286 - 291.
  • 10Ohlow MA, Lauer B, Brunelli M, et al. Incidence and predictors of pericardial effusion after permanent heart rhythm device im- plantation: prospective evaluation of 968 consecutive patients [J]. CircJ, 2013,77(4):975-981.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部