^(60)Coγ射线急慢性照射对小鼠骨、牙和毛发ESR信号的影响 被引量:1

EFFECTS OF ESR SIGNAL PROPERTIES OF MICE FEMUR, TEETH AND HAIR IRRADIATED BY DIFFERENT DOSES OF ^(60)Co γ-RAYS
在线阅读 下载PDF
导出
摘要 对昆明种雄性小白鼠给予不同剂量的急性或慢性^(60)Coγ射线整体照射(剂量范围为0—3.0Gy),分离小鼠股骨、牙齿和毛发并进行前处理后,用电子自旋共振谱仪(ESR)测定各自的信号强度。结果表明,小鼠牙齿和毛发信号无特征性峰。小鼠股骨ESR信号呈现特征峰,无论是急性照射还是慢性照射,小鼠股骨ESR信号强度随着照射剂量的增大而增高,呈现良好的直线关系,保存在福尔马林溶液中的小鼠股骨,其ESR信号强度在保存7d时明显降低(p<0.001),在室温干燥条件下保存453d的股骨ESR信号强度无明显改变。说明,小鼠股骨的最适保存条件为室温干燥。 Male, Kunming mice were irradiated by different doses of 60Co γ-rays (0-3Gy) in either acute or chronic radiation, and the hair, teeth and femora samples were studied with ESR spectrometer. While no characteristic ESR signals were found with the hair and teeth samples, ESR spectra of the femora were characterized by enhanced signal intensities with increasing dose of both acute and chronic exposures to the radiation. Storage condition of the irradiated femora samples was studied. No significant changes in the ESR signal intensities were observed with the samples kept dry at room temperatures for up to 453 days, whereas the intensity decreased significantly (P<0.001) from the samples kept in formalin for just 7 days.
出处 《辐射研究与辐射工艺学报》 CAS CSCD 北大核心 2003年第3期198-201,共4页 Journal of Radiation Research and Radiation Processing
基金 卫生部科学研究基金(98-2-46)资助
关键词 钴同位素 Γ射线 小鼠股骨 整体照射 牙齿 毛发 ESR信号强度 电子自旋共振谱仪 保存条件 Mouse femur, Hair and teeth, Whole-body irradiation, ESR signal intensity, Storage condition
  • 相关文献

参考文献9

  • 1Lloyd D C, Edwards A A, Fitzsimons E J et al. Occu Environ Med, 1994, 51(3): 713-718
  • 2Onori S, Pantaloni M, Baccaro S et al. Appl Radiat Isot,1996, 47(11-12): 1637-1640
  • 3吴可,丛建波,孙存普,田晓华,滕霞,王澍.一例辐射事故病人骨受照剂量的顺磁评估[J].中华放射医学与防护杂志,1997,17(1):43-44. 被引量:4
  • 4吴可,汤立达.^60Coγ射线照后骨组织ESR信号特性及与照射剂量的关系[J].中华放射医学与防护杂志,1993,13(4):229-231. 被引量:6
  • 5Caracelli I, Terrile M C, Mascarenhas S. Health Phys,1986, 50(2): 259-263
  • 6Onori S, Pantaloni M, Baccaro S et al. Appl Radiat Isot,1996, 47(11-12): 1637-1640
  • 7Haskell E, Hayes R, Kenner G. Radiat Meas, 1997, 27(2):325-329
  • 8Kinoshita A, Braga F J, Graeff C F et al. Appl Radiat Isot,2001, 54(2): 269-274
  • 9Copeland J F, Kase K R, Chabot G E et al. Appl Radiat Isot, 1993, 44(1-2): 101-106

二级参考文献1

  • 1吴可,中华放射医学与防护杂志,1993年,13卷,229页

共引文献8

同被引文献9

  • 1吴可,汤立达.^60Coγ射线照后骨组织ESR信号特性及与照射剂量的关系[J].中华放射医学与防护杂志,1993,13(4):229-231. 被引量:6
  • 2赵永富,哈益明,刘婷,王荣富,汪昌保.电子自旋共振波谱法检测含骨类食品的初步研究[J].辐射研究与辐射工艺学报,2007,25(5):279-282. 被引量:8
  • 3Romanyukha AA,Regulla DF.Aspects of retrospective ESR dosimetry (invited paper)[J].Appl Radiat isot,1996,47(11-12):1293-1297.
  • 4Shengli N,Pascal D,Hajo Z.Approaches to attribution of detri- mental health effects to occupational ionizing radiation exposure and their application in compensation programmes for cancer[M].Geneva:ILO,2010:66-67.
  • 5Caracelli I,Terrile MC,Mascarenhas S.Electron spin resonance dosi- metric properties of bone[J].Health Phys,1986,50(2):259-263.
  • 6Ciesielski B,Krefft K,Penkowski M,et al.Effects of water treat- ment and sample granularity on radiation sensitivity and stability of EPR signals in X-ray irradiated bone samples[J].Radiat Prot Dosimetry,2014,159(1-4):141-148.
  • 7Wieser A,Haskell E,Kenner G,et al.EPR dosimetry of bone gains accuracy by isolation of calcified tissue[J],Appl Radiat Isot,1994,45(4):525-526.
  • 8陈英,周平坤,吴可.放射损伤生物剂量估算技术研究[J].辐射防护,2008,28(6):385-391. 被引量:8
  • 9范亚光.牙釉质ESR回顾性剂量技术与剂量重建[J].国外医学(放射医学核医学分册),2002,26(2):90-92. 被引量:3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部