指出上海别墅建筑常用空调系统存在的问题 ,分析了在该类建筑中使用地源热泵空调系统的可行性 ,结合工程设计实例 ,着重介绍了U型竖埋管地下换热器的设计方法。
Points out the problems existing in commonly used air conditioning systems for villa buildings in Shanghai area. Analyses the feasibility of using ground source heat pump system in these buildings. With a design example, presents mainly the design method of U type vertical ground coil heat exchangers.
出处
《暖通空调》
北大核心
2003年第6期80-83,132,共5页
Heating Ventilating & Air Conditioning
关键词
上海
别墅
地源
热泵
空调系统设计
U型竖埋管换热器
Shanghai area, villa, ground source heat pump system, U type vertical ground coil heat exchanger