对光伏光热建筑一体化 (BIPV/T)的两种主要模式建立了理论模型 ,采用香港地区典型年的气象数据对两种BIPV/T模式的热性能进行了计算分析。与常规建筑相比 ,光伏光热建筑减少了墙体得热 ,改善了室内空调负荷状况 。
Establishes theoretical models of two primary structures of photovoltaic/thermal integrated buildings(BIPV/T). Analyses the thermal performance of the two models based on the typical meteorological data in HK. Compared with normal buildings, BIPV/T reduces the air conditioning load caused by indoor heat gain through the wall and improves building energy efficiency.