摘要
通过研究提出一种快速确定进水溶解性COD中易生物降解部分SS 的物理 化学方法。该方法以絮凝为主体 ,将可通过 0 4 5 μm滤膜的胶体物质进行絮凝沉淀 ,然后再辅以质量良好的滤膜过滤 ,二者结合可有效测定SS 值。研究结果表明 ,絮凝方法和呼吸计量法所得出的结果具有较好的相关性 ,SS(OUR)约等于 0 81SS(floc)。滤膜质量对测定结果影响很大 ,如果没有质量良好的滤膜 ,建议采用单一絮凝方法直接测定进水中的SS。
A physico-chemistry based fast measurement to determine the bio-degradable content of soluble COD in inlet raw wastewater has been advanced. Flocculent was adopted to determine Ss, by this way: the 0.45 μm penetrating colloids were flocculently settled and then fine membrane filtrated. The determined Ss by floc is correlated to that by respirometry, about 1 Ss (respiratory)=0.81 Ss (floc). The quality of the membrane causes tremendous influence to the determination. In case when no high quality membrane obtained, it is proposed to examine the Ss by single flocculent way.
出处
《给水排水》
CSCD
北大核心
2003年第11期23-26,共4页
Water & Wastewater Engineering
基金
国家自然科学基金重点项目 (50 1 380 1 0 )