期刊文献+

碳纤维增强混凝土裂纹钝化的有限元模拟与实验研究 被引量:8

Study of Crack Blunting in Carbon Fibre Reinforced Concrete and Finite Element Simulation
在线阅读 下载PDF
导出
摘要 利用电沉积技术对碳纤维增强混凝土的裂纹尖端实施钝化,利用有限元定量地模拟了整个试件的电流密度分布状况,并证明在裂纹尖端和电极附近有电流密度集中现象.裂纹尖端附近的电流密度比混凝土试件上的电流密度高出了几百倍,沉积物最先沉淀在这些地方,使得裂纹尖端的曲率半径增大,最后达到阻止裂纹的进一步扩展甚至将其修复的目的.实验验证了这一点,表明利用电沉积技术对碳纤维混凝土实行裂纹尖端钝化是一种行之有效的方法. The qualitatively currentdensity distribution of the whole CFRC sample is simulated by finite element method. At the same time that the currentdensity convergence effect is existed near the crack tip and electrode is proved. Therefore, precipitation will be deposited firstly in crack and crack tip when current is applied to the MgSO4 solution, which makes the curvature radius of crack tip increase and prevents the crack from further extending even rehabilitating crack. Final results of experiment indicate that applying electrodeposition technology is an effective method of blunting crack tip and healing crack.
出处 《华中科技大学学报(城市科学版)》 CAS 2003年第3期26-29,共4页 Journal of Huazhong University of Science and Technology
基金 国家自然科学基金重点资助项目(50238040).
关键词 碳纤维增强混凝土 裂纹 钝化 有限元 仿真模拟 smart concrete carbon fibre crack blunting finite element simulation
  • 相关文献

参考文献8

  • 1毛起,杨元霞,李卓球,沈大荣.外加剂对CFRC导电性能的影响[J].无机材料学报,1997,12(3):415-419. 被引量:7
  • 2Stefan Jacobsen, Erik J Sellevold. Self-healing of high strength concrete after deterioration by freeze/thaw [J]. Cement and Concrete Research,1996, 26 (1): 55-62.
  • 3Dry Carolyn. Matrix cracking repair and filling using active and passive modes for smart timed release of chemicals from fibers into cement matrix[J]. Smart Materials and Structures, 1994, 3(2):118-123.
  • 4H Hiraishi. Smart structure system[J]. Concrete Journal, 1998, 36 (1): 11-12.
  • 5S M Bleay, et al. A smart repair system for polymer matrix composites [J]. Composites (Part A). 2001, 32:1 767-1 776.
  • 6Jae-Suk Ryu, Nobuaki Otsuki. Rehabilitation of concrete with drying shrinkage cracks using electro-chemical technique [A]. First International Conference on Advances in Structural Engineering and Mechanics [C]. 1999. 1 349-1 354.
  • 7Mingqing Sun, et al. Size effect and loading rate dependence of the pressure-sensitivity of carbon fiber reinforced concrete [J]. Journal of Wuhan University of Technology, 1998, 13 (3): 58-61.
  • 8J-S RYU,N OTSUKI. Application of electrochemical techniques for the control of cracks and steel corrosion in concrete[J]. Journal of Applied Electrochemistry, 2002, 32: 635-639.