利用一简单的模型,从理论上证明了在化学氧碘激光器小信号增益存在依赖于系统总氧压力的最佳值,同时讨论了高压下工作的化学氧碘激光器的可行性,最后给出了确定化学氧碘激光器的最佳增益区的方法。
By means of a simple model , we have theoretically proved that in the chemical oxygen iodline laser system, there is a optimum gain zone depending on the total oxygen pressure and predicted the posibility of high pressure operation . In the end, the method is given to determine the optimum gain zone.