摘要
在分析机理的基础上 ,对密闭腔内快速传热中壁面温度的软测量方法进行了研究 ,建立了快速传热中壁面温度软测量的模型 ,给出了模型的三种解法。通过实例结果表明 :采用软测量方法 ,选择变化缓慢的温度为二次变量 ,可以实现密闭腔内快速传热中壁面温度的测量 。
Based on the analysis of principle and structure, the soft sensing method on in wall temperature during flash heat transfer in closed chamber is studied in this paper. And the soft sensing model on in-wall temperature during flash heat transfer is given. At the same time, three kinds of solutions for the model and a case are given. It is concluded that the in wall temperature during flash heat transfer in closed chamber can be measured by adopting soft sensing method and selecting the slowly changing temperature as the secondary variable. As a result, the cost of the measuring system can be decreased.
出处
《传感技术学报》
CAS
CSCD
2003年第3期355-358,362,共5页
Chinese Journal of Sensors and Actuators
基金
国家自然科学基金资助项目 ( 6 0 2 0 12 12 )
关键词
密闭腔
快速传热
壁面温度
软测量
temperature measure
flash heat transfer
closed chamber