期刊文献+

南昌电厂锅炉飞灰磨损的治理 被引量:1

How Nanchang Power Plant Dealt with Abrasion Problems Caused by Boiler Fly-Ash
在线阅读 下载PDF
导出
摘要 针对南昌电厂420t/h锅炉存在汽温偏低、飞灰磨损严重的问题,进行了热力计算和冷态空气速度场测试试验(CAVT),提出了燃烧器上摆、敷设远红外卫燃带、改变配风与送粉方式、加装均流屏筛等改造措施,使锅炉运行可靠性大大提高。 Focusing on the low steam temperature and serious fly ash abrasion problem incurred by Nanchang Power Plant's 420t/h boiler, a thermal recalculation and a cold air velocity field test(CAVT) was conducted; based on which the burner was pitched up, an infrared combustion boosting zone set up, air distribution and coal dust spraying remodelled and a flow equalizing screen installed, which considerably improved the boiler's operational reliability.
出处 《发电设备》 2003年第5期15-17,71,共4页 Power Equipment
关键词 燃煤锅炉 飞灰磨损 治理 冷态空气速度场 coal firing boiler fly ash abrasion handling cold air velocity field
  • 相关文献

参考文献4

二级参考文献9

  • 1曾汉才.引进型300MW机组贫煤锅炉燃烧器反切改造的研究[M].华中理工大学出版社,1995..
  • 2-.湖北汉川电厂2号炉燃烧调整试验报告[M].电力部热工研究院,湖北汉川电厂,1996..
  • 3-.汉川电厂2号炉大修前对流烟道流场测试报告[M].电力部热工研究院,湖北汉川电厂,1996..
  • 4-.汉川电厂2号炉大修后对流烟道流场测试报告[M].电力部热工研究院,湖北汉川电厂,1996..
  • 5-.汉川电厂2号炉尾部受热面防磨措施的模化试验研究[M].电力部热工研究院,湖北汉川电厂,1996..
  • 6杨卫宏,锅炉技术,1999年,30卷,5期,26页
  • 7赵渝渝,锅炉技术,1999年,30卷,5期,11页
  • 8赵渝渝,锅炉低温再热器飞灰磨损综合治理的研究 [D],1999年
  • 9曹汉鼎,锅炉技术,1986年,17卷,1期,1页