微生物腐蚀机制及检测方法 被引量:5

Mechanism and Detection of Microbiologically Influenced Corrosion
原文传递
导出
摘要 生物膜在自然界无处不在,但生物膜造成的腐蚀却基本上被忽略。综述了微生物尤其是硫酸盐还原菌的腐蚀机理,并对微生物腐蚀研究方法做了简单介绍,以期对火电厂微生物腐蚀的研究工作有一定的帮助。 Biofilm is ubiquitous in nature. However, corrosion caused by boifilm has still been overlooked. The corrosion mechanism of microbe,especially sulfatereducing bacteria was summarized. Various electrochemical detection methods for microbical corrosion (MIC) were reviewed and the MIC in circulating cooling system was expatiated. Moreover, from the regard of the water conservation and lowering of operation cost the concentration rate of the cooling water becomes more higher, which results in deterioration of cooling water quality and the MIC tendency is more larger. Study in this field has theoretical and practical meanings.
作者 廖强强
出处 《华东电力》 北大核心 2003年第9期40-43,共4页 East China Electric Power
基金 上海市教育委员会青年发展基金资助项目 (编号 :0 2 0 Q0 5 )
关键词 金属腐蚀 微生物腐蚀机制 生物膜 检测方法 电化学方法 microbial corrosion electrochemical methods biofilm