应用骨密度评估骨愈合的研究 被引量:9

Experimental study on quantitative assessment of fracture healing with bone mineral density determined by dual energy X-ray absorptiometry
原文传递
导出
摘要 目的 通过骨愈合过程中骨矿密度 (BMD)与力学性能间的动态变化来判断双能X线吸收骨密度测量仪 (DEXA)评估骨愈合进程的可行性。方法 将 3 0条犬造成右胫骨中段骨折并分离 4mm ,单边外固定支架固定。分别在术后 4、6、8、10、12周取双侧胫骨 ,测定BMD、弯曲刚度、扭转刚度及扭转强度 ,分析BMD与力学参数比率的关系。结果 DEXA测量骨折端 1cm区域的BMD比率与各项力学性能指标比率均有很好的线性回归关系 ,R2 分别为 0 .83 7、0 .82 4、0 .80 7。 Objective To explore the relationship between bone mineral density (BMD) and the biomechanical characteristics of healing bone and evaluate the feasibility of quantitative assessment of fracture healing with dual energy X-ray absorptiometry (DEXA).Methods In 30 beagles,a right midshaft tibial osteotomy was performed and was stabilized with a 4 mm gap using an external fixator.A group of 5 animals were euthanized at 4,6,8,10,12th week respectively after surgery.Both tibias were harvested and BMD were measured in a 1 cm region using DEXA.The bending stiffness,torsional stiffness and torsional strength were determined with biomechanical tests.Linear regressions were performed to analyze the correlation between BMD ratio and biomechanical parameter indexes.Results There were high correlation between BMD ratio and biomechanical parameter indexes (R 2=0.837,0.824,0.807 respectively).Conclusion BMD determined by DEXA is proved to be a successful indicator for the prediction of mechanical stability of healing bone.
出处 《中华实验外科杂志》 CAS CSCD 北大核心 2003年第9期827-828,共2页 Chinese Journal of Experimental Surgery
关键词 骨密度 骨折愈合 X线 BMD DEXA测量 生物力学 Bone mineral density X-ray Fracture healing Biomechanics
  • 相关文献

参考文献8

  • 1Water N J, Augat P, Krischak GD, et al. Prediction of strength of cortical bone in vitro by microcomputed tomography. Clin Biomech, 2001, 16:252-256.
  • 2Koo MWM, Yang KH, Begeman P, et al. Prediction of bone strength in growing animals using noninvasive bone mass measurements. Calcif Tissue Int, 2001,68: 230-234.
  • 3Chakkalakal DA, Lippidlo L, Wilson RF, et al. Mineral and matrix contributions to rigidity in fracture healing. J Biomech, 1990, 23:425-34.
  • 4Augat P, Merk J, Genant HK, et al. Quantitative asessment of experimental fracture repair by peripheral computed tomography. Calcif Tissue Int, 1997, 60:194-199.
  • 5Blokhuis TJ, den Boer FC, Bramer JAM, et al. Evaluation of strength of healing fractures with dual energy x-ray absorptiometry. Clin Orthop,2000, 380 : 260-268.
  • 6Tselentakis G, Owen PJ, Richardson JB, et al. Fracture stiffness in callotasis determined by dual-energy X-ray absorptiometry scanning. J Pediatric Orthop(Part B), 2001, 10 : 248-254.
  • 7Markel MD, Bogdanske JJ. The effect of increasing gap width on localized densitometric changes within tibial ostectomies in a canine model.Calcif Tissue Int, 1994, 54: 155-159.
  • 8Grier SJ, Turner AS, Alvis MR. The use of dual-energy x-ray absorptiometry in animals. Investigative Radiology, 1996, 31:50-62.

同被引文献61

引证文献9

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部