期刊文献+

波纹管内导流管破裂原因分析 被引量:2

FAILURE ANALYSIS OF A STAINLESS STEEL DIVERSION TUBE INSIDE A BELLOWS
在线阅读 下载PDF
导出
摘要 通过对导流管工况条件、破裂宏观特征、断口微观形貌及断口腐蚀产物的综合分析 ,认为该导流管属腐蚀疲劳破坏 ,引起腐蚀疲劳的交变应力来自高温高速蒸汽冲击时产生的振动 ,断口上有腐蚀性元素 ,裂纹扩展区断口呈双重锯齿状 。 A systematical analysis on service environment,macro- and microscopic morphologies of failure surfaces and corrosion products on failure surfaces showed that the failure of a diversion tube inside a bellows was resulted from corrosion fatigue.The fatigue cyclic stresses came from the vibration due to the impact of high-speed steam.Aggressive elements were found on failure surfaces,and the morphologies of failure surfaces in crack propagation region were double sawtooth,which further confirmed the above conclusion.
出处 《腐蚀科学与防护技术》 CAS CSCD 北大核心 2003年第5期299-301,共3页 Corrosion Science and Protection Technology
关键词 波纹管 导流管 破裂 腐蚀疲劳 失效分析 不锈钢 failure analysis 1Cr18Ni9Ti stainless steel diversion pipe corrosion fatigue
  • 相关文献

参考文献3

  • 1Ssuresh 王中光等译.材料的疲劳[M].北京:国防工业出版社,1993.204-223.
  • 2RESmallman著 张人佶译.现代物理冶金学[M].北京:冶金工业出版社,1980.305.
  • 3肖纪荧著.应力作用下的金属腐蚀[M].北京:化学工业出版社,1990.413.