采用有限单元离散空间域 ,视冷却水管所在单元为子结构 ,其它单元为常规单元 ,然后 ,把混凝土结构瞬态温度场的有限元控制方程表示成状态方程 ,最后 ,利用精细积分法求解。结果表明 ,子结构、状态方程和精细积分技术的引用降低了对计算机贮存量的要求和提高了冷却水管附近温度梯度的精度 。
The governing equations of the finite elements for the transient temperature field of concrete structures were expressed into t he st ate equations dispersing a spatial domain by the finite element method, regardin g th e element in which a cooling water pipe exists as a substructure, the other elem ents as common elements, and then were solved by the refined integral method. T hese results show the great advantages that the introduction of substructure, st ate equation and refined integral technology reduces requirement for computer storag e quantity, and enhances the temperature gradient accuracy off the water pipes.