摘要
分析了供热机组热、电负荷分配的特点 ,建立了供热机组负荷优化分配的数学模型。运用模拟退火算法 ,对某厂 2台机组间的热、电负荷进行了优化分配。结果表明 :该优化方法简单易行 。
The features of heat and electricity load-distribution for heat-supplying units have been analysed, a mathematic model of load-distribution optimization for heat-supplying units being established. By using the simulated annealing algorithm, an optimal distribution of heat and electricity loads between two units in a power plant has been carried out. Results show, this optimization method is simple and easy to use, can be used to enhance the economic aspect of thermal power units.
出处
《热力发电》
CAS
北大核心
2003年第7期18-20,共3页
Thermal Power Generation