期刊文献+

太原第一热电厂11#炉水冷壁管泄漏原因分析 被引量:1

An Analysis of the No.11 Boiler Water-Cooling Wall Tube Leakage in Taiyuan No.1 Thermal Power Plant
在线阅读 下载PDF
导出
摘要 针对太原第一热电厂 11#炉水冷壁管泄漏事故 ,采用多种试验手段 ,分析了裂纹的宏观形貌和微观特征 ,结果表明泄漏裂纹是由于常温和高温氧化腐蚀再加热膨胀受到约束而产生交变的热约束应力 ,而导致的腐蚀疲劳损伤。 The paper gives a reasonable analysis of the leaked out water cooling wall tube on the No.11 boiler through the careful observation both on their macroscopic outer shape and microcosmic inner property in Taiyuan No.1 Thermal Power Plnat. It is concluded that the combined action by normal temperature and high temperature oxidization corrosion and repeated heat stress due to its expansion limited conduced to its corrosion fatigue failure.
作者 吕晋兰
机构地区 太原第一热电厂
出处 《电力学报》 2003年第2期138-140,共3页 Journal of Electric Power
关键词 太原第一热电厂 锅炉 水冷壁管 泄漏 腐蚀 疲劳损伤 boiler water cooling wall tube leakage corrosion fatigue
  • 相关文献

参考文献4

  • 1电厂金属材料编写组.电厂金属材料[M].北京:水利电力出版社,1979..
  • 2吴非文.火力发电厂高温金属运行[M].北京:水利电力出版社,1978..
  • 3金属机械性能编写组.金属机械性能[M].北京:机械工业出版社,1979..
  • 4姜求志 王金瑞.火力发电厂金属材料手册[M].北京:中国电力出版社,1999..