摘要 为防止雷电火灾,分析了油气区雷电灾害的机理以及常用的防护措施;测量统计了避雷针的电晕电流及避雷针保护区内外地面电场的变化情况,总结出该地区的雷电形成、发展变化规律;研究了地面电场、电晕电流与雷电活动的关系,初步建立雷电多级报警系统,最后确定报警阈值,其中解除雷电报警应低于0.5kV/m。 This paper presents the mechanism of lighting disturbance and the general protection for the lighting fire.The properties of lighting forming and changing are obtained by measuring corona current through the lighting rod and ground electric field inside and out of protection area.The different lightingalarm threshold values are given on the basis of the relations of lighting movements to ground electric field and corona current,and PC based monitoring alarm system is developed.
出处 《青岛大学学报(工程技术版)》 CAS 2003年第2期24-28,共5页 Journal of Qingdao University(Engineering & Technology Edition)
关键词 油气区 雷电灾害 报警系统 直击雷击 感应雷击 报警阀值 避雷针 电晕电流 地面电场 oil-gas area lighting disturbance ground electric field corona current alarm-system
  • 相关文献

参考文献3

二级参考文献12

  • 1解广润,1996年
  • 2解广润,1995年
  • 3刘立本,高电压技术,1993年,4期
  • 4王衍明,大气物理学,1993年
  • 5团体著者,1991年
  • 6黄玉,电力技术,1986年,5期
  • 7葛兆军,硕士学位论文,1986年
  • 8刘继,电力技术,1985年
  • 9刘继,1984年学术年会,1984年
  • 10刘继,1982年