摘要 观察不同温度超声消融肺静脉口对电传导的影响 ,探索适合肺静脉口的最佳超声消融温度。选用健康成年犬 15只 ,随机分为 5 0℃、5 5℃及 6 0℃消融组 ,用特制的超声球囊导管在S1S1快速起搏下环状消融肺静脉口 ,观察产生电隔离的时间及消融后每隔 10min再次快速起搏观察电隔离是否存在。结果 :共消融肺静脉口 5 1个 ,实验发现 ,在消融温度为 5 0℃时 ,所有消融处均未产生电隔离 ;在消融温度为 5 5℃时多产生一过性电隔离 ;在消融温度为6 0℃时可产生有效电隔离消融温度为 6 0℃时 ,电隔离多发生在达到预设消融温度后 10s内 ,最长发生在达到预设消融温度后 2 2s。结论 :经球囊超声消融肺静脉口 ,在消融温度达到 6 0℃ ,持续 30s能够产生有效电隔离。 To explore the best ablative temperature of getting effectively electrical isolation, the orifice of pulmonary vein of fifteen mongrel dogs were ablated with through the balloon ultrasound ablation (TTB-USA) system.Predetermined temperature at 50℃,55℃,60℃ respectively,ablative time: 60 seconds. Then observed the effect of TTB-USA on electrical isolation with different ablative temperature.Results:It could not reach electrical isolation at 50℃,and get temporary electrical isolation at 55℃,almost all pulmonary veins arrive at electrical isolation within 10 seconds at 60℃,the longest eletrical isolation occurred at 22 seconds later after ablation.Conclusion: Keeping 60℃ for 30 seconds could get effectively electrical isolation on orifice of pulmonary vein.
出处 《中国心脏起搏与心电生理杂志》 2003年第3期204-206,共3页 Chinese Journal of Cardiac Pacing and Electrophysiology
关键词 心房颤动 超声消融 肺静脉口 电传导 实验研究 临床应用 电生理学 Electrophysiology Vein orifice Catheter ablation,ultrasound Atrial fibrillation,focal Canine
  • 相关文献

参考文献3

二级参考文献4

共引文献10

同被引文献5

  • 1Po SS, Scherlag BJ, Yamanashi WS, et al. Experimental model for paroxysmal atrial fibrillation arising at the pulmonary vein-atrial junctions[J]. Heart Rhythm, 2006,3(2) :201
  • 2Koichiro K, Soichi M, Chiharu M, et al. A new approach for complete isolation of the posterior left atrium including pulmonary veins for atrial fibrillation [ J ]. J Cardiovasc Electrophysiol, 2007,10 ( 18 ) : 1047
  • 3Meininger GR, Calkins H, Lickfett L, et al. Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein [ J ]. J Interv Card Electrophysiol,2003,8 (2) : 141
  • 4Wang ZB,Bai J,Li F, et al. Study of a " biological focal region" of high-intensity focused ultrasound[J]. Uhrasound Med Biol, 2003,29 (5) :749
  • 5Weld KJ, Landman J. Comparison of cryoablation, radiofrequency ablation and high-intensity focused ultrasound for treating small renal turnouts [J]. BJU Int, 2005, 96 (9) : 1224

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部