摘要 介绍了光无源器件温度冲击模拟试验中的状态实时监测的一种方法 ,给出了高低温冲击引起的附加损耗计算公式 ,并对 1× 2、2× 2两种类型的耦合器进行了实验 ,分别给出了它们各两路输出光功率变化试验曲线 ,结果表明 :在温差1 4 0℃条件下 ,温度冲击对 1× 2、2× 2耦合器造成的光功率变化幅度最大值分别小于 0 .5dB、2 .0dB。 The method of state measurement with real time for optical passive components under simulating test to thermal shock are presented in this paper, the calculated formulas to auxiliary loss by high-low temperature shock are given, the testing curves of optic power change with two output are obtained for coupler of 1×2、2×2 two types, respectively. The experiment results are shown: maximum amplitude of optic power change caused by thermal shock are lower than 0.5dB、2.0dB,separately, when the conditions of temperature difference was 140℃.
出处 《应用激光》 CSCD 北大核心 2003年第3期141-143,共3页 Applied Laser
关键词 光无源器件 温度冲击 光功率 实时监测 耦合器 光纤技术 optical passive components, temperature shock, real time measurement, coupler
  • 相关文献

参考文献2

  • 1.中华人民共和国国家军用标准GJB 1217—91电连接器试验方法[M].北京:国防科学技术委员会,1991..
  • 286B/1732/CDV: IEC 601300-- 2-- 47, Ed. 1 : Basic test and measurement procedures-- Part 2 -- 47 : tests-- Thermal Shocks, 2002.