摘要
通过对村卫生室消毒效果的监测,探讨消毒灭菌工作中存在的问题及改进的方法。按《消毒技术规范》规定的方法对室内空气和物体表面进行采样和检测。结果,各监测对象合格率分别为物体表面61.2%(2357/3852)、医务人员手74.0%(832/1124)、室内空气 50.3%(373/741)、使用中消毒液40.2%(379/943)、无菌器械89.5%(162/181)、紫外线灯69.4%(188/271),自1999~2001年检测合格率逐年上升。表明加强消毒监督监测和管理,是提高消毒工作质量的有利手段。
Monitoring of disinfection efficacy in village health stations was carried out to explore the problems and methods of improvement in disinfection and sterilization work. Sampling and examination of indoor air and surfaces of articles were carried out according to the methods stipulated in the ' Technical Guidelines for Disinfection'. The results showed that the eligibility rates of various objects monitored were as follows: surfaces of articles 61.2% (2357/3852), hands of medical personnel 74.0%(832/ 1124), indoor air 50.3%(373/ 741), liquid disinfectants in use 40.2%(379/ 943), sterile instruments 89.5%(162/ 181), ultraviolet lamps 69.4%(185 / 271). The eligibility rate increased year by year from 1999 through 2001, indicating that strengthening supervision, monitoring and administration of disinfection is a beneficial means for improving quality of disinfection work.
出处
《中国消毒学杂志》
CAS
2003年第2期139-140,共2页
Chinese Journal of Disinfection