期刊文献+

种植修复上部义齿不同牙尖斜度设计的三维有限元分析 被引量:3

3-dimensional finite element analysis of single implant-supported prosthesis with different cusp inclination designs
暂未订购
导出
摘要 目的 :通过对种植修复上部义齿9种不同牙尖斜度设计的三维有限元分析 ,研究单颗种植修复上部义齿牙合面牙尖斜度的优化设计。方法 :利用ANSYS有限元分析软件建立包括下颌骨、种植体及9种不同牙尖斜度设计的上部义齿的三维有限元模型 ,在牙合面上施加两种面载荷 ,比较不同加载方式下不同设计的种植体周围应力分布。结果 :种植体与上部结构交界处、种植体颈部、种植体根尖区、种植体颈部周围骨皮质、种植体根端周围骨松质是应力集中区 ,应力最大值在种植体与上部结构交界处。结论 :不同牙尖斜度设计的种植体上部结构中 ,25°以上牙尖斜度的设计造成种植体颈部折断的危险性显著增加 。 Objective: To study the optimization of the cusp inclination design of single implant-supported prosthesis by the way of 3-dimensional finite element method.Methods: A volunteer's mandible with a single implant was scanned by helix computer tomography, then we established a 3-dimensional finite element model in ANSYS program. The model includes the mandible, the implant and the upper prosthesis in nine designs of cusp inclination. Loading the pressure on the occlusal surfaces respectively, we compared the von Mises stress distributions around the implant. Results: There were five stress concentration areas in area between the superstructure and implant, the implant neck, implant's apex, the cortical bone around the implant neck and the lingual side of around implant's apex. The maximum von Mises stress is located in the area between the superstructure and implant.Conclusion: The designs greater than 25°leads to is the best in the three cusp inclinations. The 25°is the best design in the three cusp inclinations. Thus in clinical practice, the methods to optimize implant design is feasible.
出处 《天津医科大学学报》 2003年第2期249-252,共4页 Journal of Tianjin Medical University
关键词 种植 修复 三维有限元 Implant Rehabilitation 3-dimensional finite element analysis(3DFEA)
  • 相关文献

参考文献15

  • 1徐君伍主编.口腔修复临床与理论[M].北京:人民卫生出版社,1999.545-547.
  • 2Adell R, Lekholm U, Branemark PI. A 15 year study of osseointegrated implant in the treatment of edentulous jaw[J] .Int J Oral Surg, 1981, 10:387.
  • 3Albrektsson T, Dahl E, Enbom L, et al. Osseointegrated oral implant. A multicenter study of 8139 consecutively inserted Noblepharma implant [J]. J Periodontol, 1985, 59 : 287.
  • 4Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part Ⅰ:surgical results [J]. J Prosthet Dent, 1990, 63:451.
  • 5Hart RT, Hennebel V, Thongreda N, et al. Modeling the biomechanics of the mandible: A three - dimensional finite element study [J]. J Biomech, 1992, 25(3) : 261.
  • 6Dang DT, Dilly GL, Krejci RF.Stress analysis of tooth restored with a post and corn[J].J Dent Res, 1981, 60(7):1301.
  • 7Richard A, Rennhardt YC. Periodontal ligament stress in initiation of occlusal traumatism[J] . J Periodontal Res, 1984, 19(3) : 238.
  • 8Meijer HJA, Starmans FJM, Bosman F, et al. A comparison of three finite element models of an edentulous mandible provided with implants[J]. J Oral Rehabil, 1993, 20:147.
  • 9Stegaroiu R, Sato T, Kusakari H, et al. Influence of restoration type on stress distribution in bone around implants: A three- dimensional finite element analysis[J] . Int J Oral Maxifac Implant, 1998, 13:82.
  • 10Lundgren D, Falk H, Laurell L. Influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentitions with implant - supported fixed prostheses occluding with complete dentures[J]. Int J Maxillofac Implants, 1989, 4: 277.