摘要
在介绍给水加氧处理原理的基础上 ,详细分析了影响氧化膜形成的因素 ,介绍了我国首台亚临界压力锅炉(1 0 2 1 t/ h)进行给水加氧处理试验的试验前准备情况、试验经过、给水加氧处理运行主要控制指标及操作规范 。
The mechanism of feed water oxygen treatment is introduced that the mechanism of oxide film forms and factors affect the forming of film. Then the testing that feed water oxygen treatment is first applied to subcritical pressure boiler (1 021 t/h) is analyzed on preparation before testing, whole process, main controlled parameters and operation specification. At last it is compared technical parameters and economic benefit.
出处
《吉林电力》
2003年第3期5-8,共4页
Jilin Electric Power