期刊文献+

大型电站锅炉屏区三维涡运动的研究 被引量:7

THREE-DIMENSIONAL MOTION OF VORTICES IN THE PLATEN ZONE OF TANGENTIALLY FIRED FURNACE
在线阅读 下载PDF
导出
摘要 该文首次利用IFA300恒温式热线风速仪和六线涡量探针及其定位坐标系统,测量了HG-2008/18.2-YM2型切向燃烧煤粉炉等温模型屏区的涡量场,在上炉膛内,前分隔屏尾部,形成的湍流场不仅是三维有涡运动,而且伴随着涡的强烈脉动,沿炉膛高度、宽度、深度方向,该涡分别以3个分量(纵向涡、展向涡和横向涡)表示。首次发现:分隔屏(前屏)区尾部,炉膛右半部分有明显的分离涡,并且有些分离涡伴有方向相反的另一涡出现,分离涡的最大值,集中在炉内靠近右侧墙的地方。试验结果并表明,在右1片、右2片屏的尾部有大的展向涡和横向涡出现,横向大涡靠近右侧墙壁面。靠近右侧墙的涡量强度(2.6×103 s-1)约是靠近左侧墙涡量强度(8.75×102 s-1)的3倍,由于多组小屏绕流,使得在右1片屏与右侧墙之间的流体微团,在其尾部有最大的涡度,上炉膛内,右侧墙附近,不仅流速高,而且涡度大,为研究炉内水平烟道产生烟温偏差的成因,提供了理论依据。 The IFA300 constant temperature hot wire anemometer and the six-sensor hot-wire probe,which is located on a 3-D movable frame for coordinate setting,are firstly used to measure the vorticity field in the platen zone of HG-2008/18.2-YM2 Tangentially Fired Furnace(TFF) which is isothermal model. There is three-dimensional motion of vortices in the platen zone of TFF. The experimental results show that longitudinal,transverse and spread vortices are formed at the tail of front platen along height,width,depth of combustion chamber,respectively. It is first discovered that there are evidently separated vortices,which have longitudinal property,at the tail of the front platen in the right half of the furnace exit. Also some vortices appear accompanied by another opposite vortex. The maximum vorticity is concentra-ted near the right wall of the furnace. And the experimental results of transverse and spread vortices show that there are big transverse and spread vortices at the tail of the right platen. The big transverse vortex appears near the right wall of the furnace. The maximum vorticity (2.6×103 s-1) near the right wall is about three times as much that as near the left wall. The fine fluid ball between the right platen and the right wall has the maximum vorticity because of the flow around multi-platen. It is observed from the experimental results that the velocity is high and the vorticity is very strong near the right wall in the TFF. It provides theoretical foundation for the reason why there is thermal imbalance in the TFF.
出处 《中国电机工程学报》 EI CSCD 北大核心 2003年第5期170-175,共6页 Proceedings of the CSEE
基金 国家重点基础研究基金项目(No.G19990222) 机械工业技术发展基金项目(No.95JB1101) 中国博士后科学基金项目(中博基2002-07)~~
关键词 大型电站 锅炉 屏区 三维涡运动 炉膛 Tangentially fired furnace Platen zone Three-dimensional motion of vortices Six-sensor hot-wire probe
  • 相关文献

参考文献9

  • 1周月桂,章明川,徐通模,惠世恩.四角切向燃烧锅炉烟道烟速偏差的实验研究与数值模拟[J].中国电机工程学报,2001,21(1):68-72. 被引量:30
  • 2刘泰生,姚本荣,许晋源.切向燃烧锅炉水平烟道中烟速偏差成因的试验研究[J].中国电机工程学报,2002,22(1):49-53. 被引量:15
  • 3巴切勒GK.流体动力学引论[M].北京:科学出版社,1997.11.
  • 4Kim J H. Wirbestaerkemessungen in einer turbulenten scherschicht,Doktor-Ingeninrs[M]. Technichen Universitat Berlin, 1989.
  • 5Hisashi Matsuda, Sei-ichi lida. Coherent structures in a three dimensional wall jet[J]. Journal of Fluids Engineering. 1990, (112):462-467.
  • 6Sullivan P, Pollard A. Coherent structure identification from the analysis of hot wire data [J]. Measurement Science Technology. 1996, (7): 1498-1516.
  • 7Hussain A K M F, Clark A. On the coherent structure of the axisymetric mixing layer[J]. J Fluid Mech. 1981, (104): 263-294.
  • 8Hussain A K M F. Coherent structures-reality and myth[J]. Phys Fluids, 1983, (26): 2816-2850.
  • 9Hussain A K M F. Coherent structures and turbulence[J]. J Fluid Mech, 1986, (173): 303-356.

二级参考文献8

共引文献38

同被引文献57

  • 1王恩禄,张海燕,罗永浩,田子平.电站锅炉分配集箱静压分布参数的确定[J].上海交通大学学报,2004,38(7):1185-1187. 被引量:8
  • 2姜义道,李永兴,刘明仁.四角切圆燃烧大容量电站锅炉烟气参数场偏置问题的研究[J].动力工程,1994,14(5):16-21. 被引量:27
  • 3王志刚,禚玉群,陈昌和,徐旭常.四角切圆锅炉流场伪扩散效应网格的研究[J].中国电机工程学报,2007,27(5):22-28. 被引量:43
  • 4[4]Wang Yaqin, Sun Zhaoxing, Li Wenyan, et al, The research of con-vective superheater overtemperature in tangentially fired boiler furnace[A], International Conference on Power Engineering[C]. Tokyo,1997,363-368.
  • 5赵宗让,章明川.切向燃烧锅炉一次风逆向偏转燃烧技术的应用研究[J].中国电机工程学报,1997,17(1):54-57. 被引量:8
  • 6FLUENT6.1-User's guide[Z].Fluent Inc.,2003.
  • 7He Bo-shu,Chen Mei-qian,Yu Qiu-mei,et al.Numerical Study of the Optimum Counter-Flow Mode of Air Jets in a Large Utility Furnace[J].Computers and Fluids,2003,33:1201-1223.
  • 8Chungen Yin,Sébastien Caillat,Jean-Luc Harion,et al.Investigation of the Flow,Combustion,Heat-Transfer and Emission from a 609 MW utility Tangentially Fired Pulverized-Coal Boiler[J].Fuel,2002,81:997-1006.
  • 9Chungen Yin,Lasse Rosendahl,Thomas J Condra.Further Study of the Gas Temperature Deviation in Large-Scale Tangentially Coal-Fired Boilers[J].Fuel,2003,82:1127-1137.
  • 10Shafii M B,Faghri A,Zhang Y.Thermal modeling of unloopea and looped pulsating heat pipes[J].ASME J Heat Transfer,2002,12(3):1159-1172.