摘要
讨论了国产 2 0 0MW机组常见的若干振动问题 ,如三缸三排汽机组的接长轴不平衡 ,2号瓦摩擦和低频振动 ,三缸两排汽机组的低压缸缸体结构共振等 ,对其进行了一定的分析 ,并提出了现场相应的处理措施。
Several vibration events commonly encountered on home-made 200MW units, such as unbalance of long-jointed shaft of three-cylinder and three-exhaust units, friction and low-frequency vibration of bearing pad No.2, and resonance of low-pressure cylinder body structure on three-cylinder and two-exhaust units etc., have been discussed, as well as certain analysis of the said events being carried out, and corresponding remedical measures in the field being put forward.
出处
《热力发电》
CAS
北大核心
2003年第5期44-47,共4页
Thermal Power Generation