摘要
温差自力式调节阀在攀钢3号高炉铸铁冷却壁系统试验取得成功之后,被应用到攀钢1号高炉铜冷却壁系统中,以实现铜冷却壁冷却水量的自动调节,保护冷却壁,提高冷却水冷却能力的利用率。目前,1号高炉铜冷却璧温差自力式调节阀运行正常,已取得初步效果。
After the test of temperature difference self-force type regulating valve had met with on the casting iron cooling stave system for No. 3 BF at Panzhihua Steel.it was applied to the copper cooling stave system for No. 1 BF at Panzhihua Steel,and some initial effects had been acquired.
出处
《炼铁》
北大核心
2003年第3期17-20,共4页
Ironmaking
关键词
高炉
冷却系统
冷却壁
冷却水自动调节
温差自力式调节阀
cooling stave cooling water automatic regulaling . temperature difference self-force type regulating valve