期刊文献+

加工工艺对医用心血管支架生物相容性的影响 被引量:12

Influence of Process Techniques on Biocompatibility of Coronary Artery Stent
暂未订购
导出
摘要 设计了一种新结构的316L不锈钢心血管支架,采用激光切割和电化学抛光去除尖角的加工方法,通过3T3细胞和小鼠骨髓基质细胞培养以及人体外周血的溶血实验,研究了加工工艺对该心血管支架生物相容性的影响.采用激光切割和电化学抛光工艺,获得了设计的支架形状并消除了支架边缘的尖角;实验组和对照组对比表明,细胞的形状、数量相同,其活性和生长未受支架影响,支架没有引起溶血反应,加工工艺是合理的,没有产生细胞毒性. A new kind of coronary artery stent made of 316L stainless steel was designed and processed by using laser cutting and electrochemical polishing which was used to remove the sharp corner of the stent caused by the laser cutting. The influence of process techniques on biocompatibility of the stent was also studied through the cell culture experiments with 3T3 cell and rat medullary cell and hemolysis tests.The results of comparative experiments showed that the shapes and quantities of the cells with stent were the same as those of cells with no stent, which means that the activities of the cells were not affected by the stent.The results also showed that the stent couldn′t cause hemolysis effect. The process techniques of the coronary artery stent were reasonable and free of biologic toxicity.
出处 《天津大学学报(自然科学与工程技术版)》 EI CAS CSCD 北大核心 2003年第3期374-379,共6页 Journal of Tianjin University:Science and Technology
关键词 医用心血管支架 生物相容性 加工工艺 激光切割 电化学抛光 溶血反应 coronary artery stent process techniques biocompatibility
  • 相关文献

参考文献7

二级参考文献48

  • 1马根山,黄峻,王敬良,马文珠,王世栋,吴晓震.镍钛形状记忆合金血管内支架组织相容性实验研究[J].中国生物医学工程学报,1995,14(3):198-201. 被引量:20
  • 2刘阳,孙玉鹗,黄孝迈,江朝光,郭锦芳,成玉英.镍钛记忆合金气管内植入的医学基础研究[J].中国生物医学工程学报,1996,15(3):245-248. 被引量:11
  • 3王小祥,毛志远,曹征旺,秦仁义,彭淑牖,江献川.TiNi形状记忆合金腐蚀及细胞毒性的研究[J].中国生物医学工程学报,1996,15(4):374-377. 被引量:26
  • 4[1]Bertrand OF,Sipehia R,Mongrain R,et al.Biocompatibility aspects of new stent technology[J].J Am Coll Cardiol,1998;32:562
  • 5[2]Hehrlein C,Zimmerman M,Metz J,et al.Influence of surface texture and charge on the biocompatibility of endovascular stents[J].Coronary Artery Dis,1995;6:581
  • 6[3]Van der Giessen W,Lincoff A,Schwartz R,et al.Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries[J].Circulation,1996;94:1690
  • 7[4]Malik N,Gun J,shepherd L,et al.Phosphorylcholine-coated stents in porcine coronary arteries:angiographic and morphometric assessment [abstract][J].Eur Heart J,1997;18:152
  • 8[5]Harder C,Rzany A,Schaldach M.Coating of vascular stents with antithrombogenic amorphous silicon carbide[J].Progr Biomed Res,1999;4:71
  • 9[6]Lincoff A,Furst J,Ellis S,et al. Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model[J].J Am Coll Cardiol,1997;29:808
  • 10[7]Topol EJ,Serruys PW.Frontiers in interventional cardiology.Circulation,1998;98:1802

共引文献24

同被引文献172

引证文献12

二级引证文献75

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...