摘要
高层民用建筑的加压送风系统是建筑物防排烟系统的重要组成部分之一,涉及室内人员的生命安全.结合工程实践,参考《高层民用建筑设计防火规范》(GB50045 95),阐述了高层民用建筑加压送风设计中送风范围、送风量大小、送风口型式、送风部位余压与泄压装置、风道、加压送风机等的设计,可供设计者参考.
According to the experiences in engineering and the code for fire protection design of tall buildings(GB50045?95),this paper expounds the air supply range,airflow rate,air supply inlet,excess pressure,pressure relief device,air duct and supply fan for the pressurization air supply design of high?rice buildings.
出处
《焦作工学院学报》
2003年第3期197-199,共3页
Journal of Jiaozuo Institute of Technology(Natural Science)