摘要 目的 评价经导管Amplatzer封堵器治疗继发孔型房间隔缺损(ASD)疗效。方法 21例患者在X线透视及经食管超声心动图(TEE)监视下经导管置入Amplatzer封堵器治疗ASD。 结果 术前经TEE检查示ASD直径6~32mm,平均 (20.5±7.1)mm。ASD球囊伸张直径9~34mm ,平均 (23.3±7.7)mm。Amplatzer封堵器直径10~38mm ,平均 (25.9±8.1)mm。21例均获得封堵成功 ,术中未发生任何并发症。结论 经导管Amplatzer封堵器治疗ASD是一种有效、安全的介入治疗方法。 Objective To evaluate the efficiency of transcatheter closure of secundum atrial septal defect (ASD) with Amplatzer occluder device.Methods Twenty-one patients with ASD was treated using Amplatzer occluder device through the percutaneous procedure under fluoroscopy and transesophageal echocardiography (TEE) guidance.Results The mean diameter of ASD was 20.5 ± 7.1mm (ranged from 6 to 32mm)shown by TEE before the procedure,The mean balloon stretched diameter of the ASD was 23.3±7.7mm (ranging from 9 to 34 mm).The mean diameter of the Amplatzer occluder selected was 25.9±8.1mm (ranging from 10 to 38 mm).For two cases with double ASD,Two occluder device of 22 and 10 mm in diameter were used in one patient,a larger occluder device of 28 mm in diameter was used for closing two defects in the other patient with good result.All patients were treat successfully.The success rate of placement of the Amplatzer occluder was 100%.No complications occurred.All of 21 patients was no residual shunt found during 1~18 months follow-up.Conclusion Transcatheter closure of secundum ASD using Amplatzer septal occluder device was an efficient and safe nonsurgical method.
出处 《浙江医学》 CAS 2003年第4期198-199,206,共3页 Zhejiang Medical Journal
关键词 AMPLATZER封堵器 介入治疗 继发孔型 房间隔缺损 超声心动图 Atrial septal defect Cardiac catheterization
  • 相关文献

参考文献7

  • 1戴汝平,刘延玲,张戈军,曾筝,徐仲英,李澎,唐红伟,蒋世良.应用Amplatzer封堵器介入治疗房间隔缺损疗效评价(附60例报告)[J].中华心血管病杂志,2000,28(2):87-91. 被引量:180
  • 2Masura J, Gavora P, Formanek A, et al. Transcatheter closure of secundum atrial septal defects using the new self- centering Amplatzer septal occluder:initial human experience. Cathet Cardiovasc Diagn,1997.42(4) :388.
  • 3Thanopoulos BO,I.askari CV,Tsaousis GS, et al. Closure of atrial septal defects with the Amplatzer occlusion device: Preliminary results.J Am Coll Cardiol, 1998,31 ( 5 ) : 1110.
  • 4Kaulitz R, Paul T, Hausdod G. Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device(Caxtlio SEAL). Heart, 1998,80(1) :54.
  • 5Formigari R, Santoro G, Rossetti L, et al. Comparison of three different atrial septal defect occlusion devices. Am J Cardiol, 1998,82(5) :690.
  • 6Rao PS, Sedris EB, Hausdod G, et al. International experience with secundum atrial septal defect occlusion by the buttoned device. Am Heart J, 1994,128(5) : 1022.
  • 7Hijazi ZM, Bova S, Rhodes J. Simultaneous transcatheter closure of two secundum atrial septal defects using AmplatzerTM septal occluder. J Intervent Cardiol, 1998,11 ( 2 ) : 181.

二级参考文献2

  • 1Sharafuddin M J A,Circulation,1997年,95卷,2162页
  • 2Rao P S,Am Heart J,1994年,128卷,1022页

共引文献179

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部