期刊文献+

5MW低功率堆物理计算 被引量:1

The Physical Computation for 5MW Low Power Reactor
在线阅读 下载PDF
导出
摘要 本文介绍5MW 低功率堆(5MW LPR)的物理设计。堆芯32盒燃料元件按入堆初始燃耗分三区布置,可提供的总后备反应性△k_(eff)=0.09084。后备反应性的裕量很大,运行寿期受入堆元件初始燃耗的限制。卸料元件^(149)Sm 含量的减少释放正的反应性,故在达到平衡氙后的几天里,将会引起控制棒下插。 The physical design for 5MW Low Power Reactor is introd-uced in this paper.The spent fuel elements,total 32,were partitio-naly loaded in three zones to take account of their initial burnupdifference.The excess reactivity,△k_(eff)=0.09084,can be providedwith the loading pattern.The core lifetime is only limited bythe limitation of the fuel burnup becouse of so big excess reac-tivity.In a few days after ^(115)Xe content reached its equilibrium,the control rods will insert partly to cancel the positive reacti-vity released by the ^(149)Sm consumption.
出处 《核动力工程》 EI CAS CSCD 北大核心 1992年第4期7-11,22,共6页 Nuclear Power Engineering
关键词 低功率堆 扩散 燃耗 反应堆 5MW Low Power Reactor Diffusion and burnup computation