摘要 对铱化合物中的常见微量杂质Al,Ba,Au,Pd,Pt,Ru,Rh进行了分析研究。利用ICP-AES仪器的优异性能,通过对基体效应、光谱干扰、酸度影响、等离子体测定条件等方面的考察,确定了在铱基体中共存微量离子的检测条件。各离子的检出限分别为:Pt0 39μg/mL,Pd0 03μg/mL,Al0 051μg/mL,Ba0 0027μg/mL,Au0 025μg/mL,Ru0 045μg/mL,Rh0 13μg/mL。各金属离子回收率:95%~102%。相对标准偏差RSD均小于10%。本文所建立的方法,准确、快速、方便,完全能满足该类试样分析的要求。 A new method for the determination of impurity ions in H3IrCl6 by ICP-AES has been establishedThe operation parameters of ICP-AES,the effects of inorganic acid,the influence of matrix and coexisting ions have been testedThe results indicated that the common impurity ions could be determined directly with calibration curve by ICP-AES without matrix matching in a 5%(volume fraction)hydrochloric acid as mediumThe detection limits were 039μg/mL for Pt,003μg/mL for Pd,0051μg/mL for Al,00027μg/mL for Ba,0025μg/mL for Au,0045μg/mL for Ru,013μg/mL for Rh;All these trace impurity ions were determined with recovery of 95%-102%,the RSDs were all less than 15%The method has been applied to determine common impurity ions in HIrCl4 with satisfactory results,and it is accurate,convenient and efficient
出处 《冶金分析》 CAS CSCD 北大核心 2003年第2期20-23,共4页 Metallurgical Analysis
关键词 铱化合物 杂质 测定 ICP—AES ICP-AES matrix Ir impurity ions
  • 相关文献

参考文献5

二级参考文献14

  • 1许生杰,分析化学,1986年,14卷,12期,909页
  • 2赵敏政,分析化学,1985年,13卷,6期,436页
  • 3团体著者,岩石矿物分析,1979年
  • 4团体著者,分析化学,1973年,1卷,3期,72页
  • 5张玉祥,祝贺卢嘉锡、蔡启瑞教授从事化学工作五十年学术讨论会论文集,1986年
  • 6张玉祥,高等学校化学学报,1985年,6卷,1期,699页
  • 7鲍其儿,分析化学,1974年,2卷,4期,225页
  • 8赵敏政,分析化学,1985年,13卷,6期,436页
  • 9赵敏政,分析化学,1984年,12卷,10期,920页
  • 10团体著者,分析化学,1973年,1卷,3期,72页

共引文献33

同被引文献664

引证文献5

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部