摘要
交流发电机联线错故障可以通过较简单的试验测试出来,本文通过计算和公式推导,导出联线错故障与三相电压不平衡关系。
The fault of wrong connections of the a. c. generartor can be measured by a simple test. In this paper, the relations between wrong connections and unbalanced three-phase voltages are obtained by calculation and derivation of equation.
出处
《防爆电机》
2003年第1期37-38,共2页
Explosion-proof Electric Machine