期刊文献+

原油储罐底板电化学保护及监测分析 被引量:2

Electro-chemical Protection for the Bottom Plates of Crude Oil Storage Tanks and Analysis
在线阅读 下载PDF
导出
摘要 兰州石化公司 6座大容量原油储罐的罐底板相继穿孔泄漏 ,通过分析指出为Cl-引起的电化学腐蚀所造成。在 2 0 0 0~ 2 0 0 1年期间 ,对 3座原油罐的罐底板及距底 1.5mm以上的罐壁采取了环氧玻璃鳞片涂料 +铝合金牺牲阳极联合保护 ,其保护电位可稳定在 - 9.0~ 1.0 0V范围。 The bottom plates of six large crude oil tanks in Lanzhou Petrochemical Company leaked. The analysis found that the leakage was caused by the electro-chemical corrosion by Cl -. From 2000 to 2001, the bottom plates and wall plates 1.5 m from the bottom of 3 tanks were protected by epoxy glass flake coating and aluminum alloy anode whose electric potential could be maintained at -9.0~1.00 V. The method for monitoring the protection electric potential of the bottom plates was introduced.
出处 《石油化工腐蚀与防护》 CAS 2003年第1期37-40,共4页 Corrosion & Protection In Petrochemical Industry
关键词 原油储罐底板 电化学保护 腐蚀 阴极保护 玻璃鳞片涂料 电位监测 bottom plate of crude oil tank, corrosion, cathodic protection, glass flake coating, electric potential monitoring