期刊文献+

重油加氢装置反应系统高压空冷器的腐蚀 被引量:14

Corrosion of High-pressure Air Cooler in Reactor System of Heavy Oil Hydrocracking Unit
在线阅读 下载PDF
导出
摘要 针对胜利炼油厂重油加氢装置反应系统高压空冷器E - 13 40 / 13 41腐蚀泄漏事故进行调查分析 ,确定腐蚀为NH4 Cl和NH4 HS沉积引起的垢下腐蚀 ,并从工艺操作、材质升级、监测等方面提出了防护措施 :添加多硫化铵缓蚀剂 ,提高注水量 。 The analysis of the corrosion leakage of the high-pressure air coolers E-1340/1341 in the reactor system of the heavy oil hydrocracking unit in Shengli Refinery concluded that the corrosion was the under-deposit corrosion caused by the settlement of NH 4Cl and NH 4HS. The protection measures were suggested in respect of process operation, material upgrading and monitoring etc. Addition of ammonium polysulfide corrosion inhibitor, increased water injection, selection of nickel-based alloy and strengthened corrosion monitoring could effectively control the corrosion of the air coolers.
出处 《石油化工腐蚀与防护》 CAS 2003年第1期33-36,共4页 Corrosion & Protection In Petrochemical Industry
关键词 重油加氢装置 反应系统 高压空冷器 腐蚀 镍基合金 监测 high-pressure hydrogenation, high-pressure air cooling, corrosion, Ni-based alloy, monitoring
  • 相关文献

参考文献4

  • 1[1]R L Piehl. Survey of Corrosion in Hydrocarcker Effluent Air Coolers.Materials Performance, 1976,15(1): 15 ~ 20
  • 2[2]化学工业部化工机械研究所主编.腐蚀与防护手册-腐蚀理论、试验及监测.北京:化学工业出版社,1993
  • 3[3]C Harvey and A Singh. Mitigate Failures for Reactor Effluent Air Coolers. Hydrocarbon Processing, 1999,78(10) :59 ~ 72
  • 4[4]J Turner. Control corrosion in washwater systems. Hydrocarbon Processing, 1997,76 (6) :87 ~ 96